Belden 9556 060, Power Limited Tray Cable 12C 18 AWG 300V PVC, Chrome Jacket

SKU:Belden 9556 060
● In stock
Description
Belden 9556 060 is an instrumentation cable with 6 pair 18 AWG (19x30) TC - Tinned Copper conductors, PVC - Polyvinyl Chloride insulation, and a PVC - Polyvinyl Chloride outer jacket in Chrome. It features an overall Beldfoil® shield with 100% coverage and an 18 AWG (7x26) TC drainwire to help reduce noise in signal wiring. The cable is rated 300 V (PLTC, CMG) with UL temperature 105°C and an operating range of -30°C to +105°C. A PP - Polypropylene Tape separator and ripcord support easier handling during installation.
Belden 9556 060 Key Features
- The 6 pair construction supports multi-signal instrumentation and control wiring in a single cable run.
- 18 AWG (19x30) TC - Tinned Copper stranded conductors are specified for reliable signal transmission.
- An overall Beldfoil® shield with 100% coverage and Bi-Laminate (Alum+Poly) tape helps reduce electrical noise in sensitive circuits.
- A PVC - Polyvinyl Chloride outer jacket in Chrome with ripcord supports easier handling and jacket removal.
- Rated 300 V (PLTC, CMG) for installations requiring these markings.
Belden 9556 060 Applications
- Use in instrumentation and industrial control/monitoring systems where reliable signal transmission is required.
- Support sensor wiring in environments where shielding is needed to help manage electrical noise.
- Connect valves and positioners in control circuits.
- Carry signal loops and analog control signals including 4-20mA and 0-10V.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of elements | 6 |
| Element type | pair(s) |
| Conductor size | 18 AWG |
| Stranding | 19x30 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.019 in (0.48 mm) |
| Nom. insulation diameter | 0.081 in (2.1 mm) |
| Color Code | ICEA Chart E2 |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 18 AWG (7x26) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Separator | PP - Polypropylene Tape |
| Jacket nominal thickness | 0.053 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.512 in (13.0 mm) |
| Armor | No |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance (Cond-to-Shield) | 54 pF/ft (180 pF/m) |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Max. current | 3.5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 4.98 Ohm/1000ft (16.3 Ohm/km) |
| Operating temperature | -30°C to +105°C |
| Temperature table notes | AWM 80°C |
| Stationary min. bend radius | 5.1 in (130 mm) |
| Installation min. bend radius | 5.1 in (130 mm) |
| Max Pull Tension | 319 lbs (145 kg) |
| Bulk cable weight | 145 lbs/1000ft |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, T-29-520, IEEE 1202 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
| Item Type | Belden Instrumentation Cable |
| Other Part Numbers | 9556 060100, 9556 060250, 9556 060500, 9556 0601000, UPC 612825255918 |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.