Belden 9580 002, Multi Conductor Cable 2C 14 AWG PVC, Red Jacket

SKU:Belden 9580 002
$1,319.63
● In stock
Description
Belden 9580 002 is a 2-conductor 14 AWG fire alarm cable with solid bare copper conductors, PVC insulation, and a red PVC outer jacket. It is rated FPLR for riser applications and meets UL1666 riser flammability requirements. Electrical characteristics include a 300 V UL voltage rating and max. current of 18 Amps per conductor at 25ºC. It supports an operating range of -40°C to +105°C.
Belden 9580 002 Key Features
- This 2-conductor 14 AWG cable uses solid bare copper conductors.
- It features PVC insulation and a red PVC outer jacket.
- It is rated FPLR for riser applications and complies with UL1666 riser flammability requirements.
- Electrical ratings include a 300 V UL voltage rating and max. current of 18 Amps per conductor at 25ºC.
- It supports an operating range of -40°C to +105°C.
Belden 9580 002 Applications
- Use it for fire alarms and related fire alarm wiring needs.
- It is suitable for indoor applications where low-voltage signal and control wiring is required.
- It supports low voltage analog signals such as 4-20ma and 0-10v circuits.
- It works for low voltage control circuits including 24v.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor Material | BC - Bare Copper |
| Conductor stranding | Solid |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness (insulation) | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.20 in (5.1 mm) |
| Color Code | Black, Red |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (outer jacket) | 0.042 in (1.1 mm) |
| Nom. diameter | 0.303 in (7.70 mm) |
| Jacket Color | Red |
| Shield | No |
| Nom. conductor DCR | 2.62 Ohm/1000ft (8.60 Ohm/km) |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| UL temperature | 105°C |
| Stationary min. bend radius | 2.42 in (61.5 mm) |
| Installation min. bend radius | 2.42 in (61.5 mm) |
| Max Pull Tension | 124 lbs (56.2 kg) |
| Bulk cable weight | 50 lbs/1000ft (74 kg/km) |
| Environmental suitability | Indoor, Outdoor |
| NEC / UL compliance | Article 760, FPLR |
| NEC rating | UL Listed Art 760 Riser - Fire Alarm |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | FAS105 |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | California State Fire Marshall |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9580 002100, 9580 002250, 9580 002500, 9580 0021000, UPC 612825256212 |