Belden 9583 002, Multi Conductor Cable 2C 12 AWG PVC, Red Jacket

SKU:Belden 9583 002
● In stock
Description
Belden 9583 002 is a 2 conductor 12 AWG fire alarm and control cable designed for indoor riser installations. It uses solid bare copper conductors with PVC insulation, plus an overall Beldfoil® shield and a 16 AWG (19x29) TC drainwire to support grounding and help reduce noise in low voltage signaling. The red PVC outer jacket supports quick field identification, and the cable is rated FPLR with UL1666 riser and FT4 flammability compliance.
Belden 9583 002 Key Features
- 2 conductor construction with 12 AWG solid bare copper conductors.
- PVC - Polyvinyl Chloride insulation with black and red color code.
- Overall Beldfoil® shield (tape) with Bi-Laminate (Alum+Poly) and 100% coverage.
- 16 AWG (19x29) TC drainwire for grounding support.
- Red PVC - Polyvinyl Chloride outer jacket for quick identification.
- Rated FPLR and meets UL1666 riser and FT4 flammability requirements.
Belden 9583 002 Applications
- Commonly installed in fire alarm systems where dependable signaling is required.
- Designed for indoor applications, including indoor riser environments.
- Supports low voltage analog signals (4-20ma, 0-10v, ...) in control and signaling circuits.
- Suitable for low voltage control (24v, …) wiring in building and system control runs.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Max. current | 21 Amps per Conductor at 25ºC |
| UL Voltage Rating | 300 V |
| Conductor DCR (nom.) | 1.6 Ohm/1000ft |
| Shield DCR (nom.) | 3.5 Ohm/1000ft (11 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 86 pF/ft (280 pF/m) |
| Capacitance, Cond-to-other (conds + Shield) (nom.) | 160 pF/ft (520 pF/m) |
| Inductance (nom.) | 0.18 µH/ft (0.59 µH/m) |
| Insulation thickness (nom.) | 0.023 in (0.58 mm) |
| Insulation diameter (nom.) | 0.127 in (3.23 mm) |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall cable diameter (nominal) | 0.343 in |
| Bulk cable weight | 80 lbs/1000ft |
| UL temperature | 105°C |
| Operating | -20°C To +75°C |
| Bend radius (stationary min.) | 5.14 in (131 mm) |
| Bend radius (installation min.) | 5.14 in |
| Max Pull Tension | 197 lbs (89.4 kg) |
| Environmental suitability | Indoor, Sunlight Resistance |
| NEC / UL compliance | Article 760, FPLR |
| CEC / C(UL) compliance | FAS105 |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | California State Fire Marshall |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9583 002100, 9583 002250, 9583 002500, 9583 0021000, UPC 612825256250 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.