Belden 9613 060, Multi Conductor Computer Cable 8C 24 AWG Shield PVC

Description
Belden 9613 060 is a Computer EIA RS-232 Cable designed for reliable signal transmission in control, communications, and panel wiring. It is built with 8 x 24 AWG stranded (7x32) TC - Tinned Copper conductors and SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation. For EMI/RFI reduction, it includes an overall Beldfoil® (100% coverage) plus a Tinned Copper braid shield (65% coverage). The PVC - Polyvinyl Chloride jacket is Chrome, with a 0.240 in (6.10 mm) nominal overall diameter for indoor installations.
Belden 9613 060 Key Features
- Computer EIA RS-232 Cable construction for signal transmission in control, communications, and panel wiring.
- 8 x 24 AWG stranded (7x32) TC - Tinned Copper conductors for multi-conductor connectivity.
- Overall shield: Beldfoil® (100% coverage) + Tinned Copper braid shield (65% coverage) to help reduce EMI/RFI.
- PVC - Polyvinyl Chloride jacket in Chrome with a 0.240 in (6.10 mm) nominal overall cable diameter.
- Environmental suitability: indoor.
Belden 9613 060 Applications
- Supports RS-232 applications where consistent signal transmission is required.
- Used in computer communications links for data and control connectivity.
- Suitable for low voltage analog signals (4-20ma, 0-10v, ...) in control and monitoring circuits.
- Handles low voltage digital control (24v, …) in automation and control wiring.
- Works for line level audio signal runs where shielded multi-conductor wiring is needed.
- Fits panel wiring layouts for organized internal connections in control and communications panels.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 8 |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
| Insulation nominal thickness | 0.011 in (0.28 mm) |
| Insulation color code | Black, White, Red, Green, Brown, Blue, Orange, Yellow |
| Shield tape material | Bi-Laminate (Alum+Poly) |
| Shield braid material | Tinned Copper (TC) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.035 in (0.89 mm) |
| Jacket Color | Chrome |
| Nom. conductor DCR | 25 Ohm/1000ft (82 Ohm/km) |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 55 pF/ft (180 pF/m) |
| Max. current | 1.5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 7.3 Ohm/1000ft (24 Ohm/km) |
| UL Voltage Rating | 300 V (CMG), 300 V (UL AWM 2464) |
| Overall cable diameter (nominal) | 0.240 in (6.10 mm) |
| Bend radius (stationary min.) | 2.4 in (61 mm) |
| Bend radius (installation min.) | 2.4 in (61 mm) |
| Max Pull Tension | 69 lbs (31 kg) |
| Bulk cable weight | 37 lbs/1000ft (55 kg/km) |
| Operating temperature | -30°C to +80°C |
| UL temperature | 80°C (UL AWM 2464) |
| Flammability / reaction to fire | UL1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9613 060100, 9613 060250, 9613 060500, 9613 0601000, UPC 612825256441 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.