Belden 9614 060, Multi Conductor Computer Cable 9C 24 AWG Shield PVC

SKU:Belden 9614 060
● In stock
Description
Belden 9614 060 is a 9-conductor computer EIA RS-232 cable with 24 AWG stranded (7x32) tinned copper conductors and SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation. It uses an overall Beldfoil® shield (100% coverage) plus a tinned copper (TC) braid shield (65% coverage) to help reduce EMI for low-voltage signal transmission. This cable has a PVC - Polyvinyl Chloride jacket in Chrome and is rated 300 V (CMG), 300 V (UL AWM 2464) with an operating temperature of -30°C to +80°C.
Belden 9614 060 Key Features
- 9 conductors support multi-signal RS-232 and control wiring needs in a single run.
- 24 AWG stranded (7x32) tinned copper conductors provide flexible stranded construction with tinned copper material.
- SR-PVC - Polyvinyl Chloride (Semi-Rigid) insulation has a nominal thickness of 0.011 in (0.28 mm) and a nominal insulation diameter of 0.044 in (1.1 mm).
- Dual shielding combines Bi-Laminate (Alum+Poly), 100% tape coverage with a tinned copper (TC), 65% braid shield.
- PVC - Polyvinyl Chloride jacket in Chrome has a nominal jacket thickness of 0.035 in (0.89 mm) and a nominal jacket diameter of 0.255 in (6.48 mm).
- Voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C; UL temperature: 80°C.
- Environmental suitability: Indoor (Not Riser or Plenum), Indoor.
Belden 9614 060 Applications
- Use it for RS-232 applications where multiple signal conductors are needed for serial communication wiring.
- Support computer communications wiring in systems that require shielded, low-voltage signal transmission.
- Apply it to low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation signal paths.
- Choose it for low voltage digital control (24v, …) wiring where shielded conductors help maintain signal integrity.
- Connect it in line level audio applications where shielding helps reduce interference.
- Install it for panel wiring where organized multi-conductor terminations are required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nom. conductor DCR | 25 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 55 pF/ft (180 pF/m) |
| Max. current | 1.5 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 7.5 Ohm/1000ft (25 Ohm/km) |
| Color Code | Black, White, Red, Green, Brown, Blue, Orange, Yellow, Purple |
| Overall cable diameter (nominal) | 0.255 in (6.48 mm) |
| Bulk cable weight | 41 lbs/1000ft |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 74 lbs (34 kg) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9614 060100, 9614 060250, 9614 060500, 9614 0601000, UPC 612825256472 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.