Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 9841 060, 24 AWG 7x32 TC Shielded 1000’ Reel Drain Wire, Chrome Jacket

Belden 9841 060

SKU:Belden 9841 060

Request a Quote

Request a Quote

Description

Specifications

Belden 9841 060, 24 AWG 7x32 TC Shielded 1000’ Reel Drain Wire, Chrome Jacket specifications
AttributeValue
Pairs1
Conductor size24 AWG
Stranding7x32
Conductor MaterialTC - Tinned Copper
Insulation MaterialPE - Polyethylene
Insulation nom. thickness0.023 in (0.58 mm)
Nom. insulation diameter0.068 in (1.7 mm)
Color CodeWhite/Blue Stripe & Blue/White Stripe
Overall shieldBeldfoil® + Tinned Copper braid
Tape shield materialBi-Laminate (Alum+Poly)
Tape coverage100%
Braid shield materialTinned Copper (TC)
Braid coverage90%
Drainwire type24 AWG (7x32) TC
Jacket MaterialPVC - Polyvinyl Chloride
Jacket ColorChrome
Jacket nom. thickness0.035 in (0.89 mm)
Nom. diameter0.232 in (5.89 mm)
Overall cable diameter (nominal)0.232 in (5.89 mm)
Jacket OD +/-0.020
Nom. characteristic impedence120 Ohm
Nom. conductor DCR24 Ohm/1000ft (79 Ohm/km)
Nom. outer shield DCR3.4 Ohm/1000ft (11 Ohm/km)
Nom. capacitance cond-to-cond12.8 pF/ft (42.0 pF/m)
Nom. capacitance cond-to-other (conds + Shield)23 pF/ft (75 pF/m)
Nom. delay1.6 ns/ft
Nom. velocity of prop.66%
Max. current2.1 Amps per Conductor at 25ºC (10°C Temperature Rise)
Nom. insertion loss (attenuation) [dB/100ft]0.6 at 1 MHz
UL Voltage Rating300 V (CM), 30 V (UL AWM 2919)
Environmental suitabilityIndoor
Operating temperature-30°C to +80°C
UL temperature80°C
Bend radius (stationary min.)2.5 in (64 mm)
Bend radius (installation min.)2.5 in (64 mm)
Max Pull Tension72.3 lbs (32.8 kg)
Bulk cable weight36 lbs/1000ft (54 kg/km)
Overall cabling lay length2.5 Inch
Overall cabling lay directionLeft hand
Overall cabling lay twists4.8 twist/ft
NEC / UL complianceArticle 800, CM
CEC / C(UL) complianceCM
AWM complianceAWM 2919
Flammability / reaction to fireUL 1685 UL Loading, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)DMX-512
Plenum number82841, 89841
Non-Plenum number9841ZH
Item TypeBelden Multi-Pair Cable
Other Part Numbers9841 060100, 9841 060250, 9841 060500, 9841 0601000
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.