Belden 9841 060, 24 AWG 7x32 TC Shielded 1000’ Reel Drain Wire, Chrome Jacket

Description
Belden 9841 060 is a 1-pair, 24 AWG (7x32) TC - Tinned Copper shielded cable with PE - Polyethylene insulation and a chrome PVC - Polyvinyl Chloride jacket. It uses an overall Beldfoil® + Tinned Copper braid shield (100% tape coverage, 90% braid coverage) and includes a 24 AWG (7x32) TC drain wire for grounding in electrically noisy environments. This cable is UL CM rated for indoor installations and is designed for RS-485 and other low-voltage analog and digital control signals. It has 120 Ohm nominal characteristic impedence and low capacitance for stable data transmission and control performance.
Belden 9841 060 Key Features
- 1-pair construction with 24 AWG (7x32) TC - Tinned Copper conductors.
- Overall shielding combines Beldfoil® + Tinned Copper braid with 100% tape coverage and 90% braid coverage.
- Includes a 24 AWG (7x32) TC drain wire for grounding.
- PE - Polyethylene insulation with White/Blue Stripe & Blue/White Stripe color code.
- Chrome PVC - Polyvinyl Chloride jacket with UL CM rating for indoor installations.
Belden 9841 060 Applications
- Use it for RS-485 serial communication links in electrically noisy environments.
- Support serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
- Choose it for POS and computer communications where shielded signal cabling is needed.
- Apply it to low voltage analog signals (4-20ma, 0-10v, ...) in control and monitoring circuits.
- Use it for low voltage digital control (24v, …) signal wiring.
- Run it for line level audio signal runs.
- Install it for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Pairs | 1 |
| Conductor size | 24 AWG |
| Stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene |
| Insulation nom. thickness | 0.023 in (0.58 mm) |
| Nom. insulation diameter | 0.068 in (1.7 mm) |
| Color Code | White/Blue Stripe & Blue/White Stripe |
| Overall shield | Beldfoil® + Tinned Copper braid |
| Tape shield material | Bi-Laminate (Alum+Poly) |
| Tape coverage | 100% |
| Braid shield material | Tinned Copper (TC) |
| Braid coverage | 90% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Jacket nom. thickness | 0.035 in (0.89 mm) |
| Nom. diameter | 0.232 in (5.89 mm) |
| Overall cable diameter (nominal) | 0.232 in (5.89 mm) |
| Jacket OD +/- | 0.020 |
| Nom. characteristic impedence | 120 Ohm |
| Nom. conductor DCR | 24 Ohm/1000ft (79 Ohm/km) |
| Nom. outer shield DCR | 3.4 Ohm/1000ft (11 Ohm/km) |
| Nom. capacitance cond-to-cond | 12.8 pF/ft (42.0 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 23 pF/ft (75 pF/m) |
| Nom. delay | 1.6 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.1 Amps per Conductor at 25ºC (10°C Temperature Rise) |
| Nom. insertion loss (attenuation) [dB/100ft] | 0.6 at 1 MHz |
| UL Voltage Rating | 300 V (CM), 30 V (UL AWM 2919) |
| Environmental suitability | Indoor |
| Operating temperature | -30°C to +80°C |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.5 in (64 mm) |
| Bend radius (installation min.) | 2.5 in (64 mm) |
| Max Pull Tension | 72.3 lbs (32.8 kg) |
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Overall cabling lay length | 2.5 Inch |
| Overall cabling lay direction | Left hand |
| Overall cabling lay twists | 4.8 twist/ft |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2919 |
| Flammability / reaction to fire | UL 1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | DMX-512 |
| Plenum number | 82841, 89841 |
| Non-Plenum number | 9841ZH |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 9841 060100, 9841 060250, 9841 060500, 9841 0601000 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.