Belden 9888 010 is a 50 Ohm triaxial coax designed for computer and instrumentation applications. It features an 11 AWG (7x19) BC - Bare Copper stranded conductor with PE - Polyethylene (Foam) insulation and a Double Braid Shield for shielding performance. The cable uses a PE - Polyethylene inner jacket and PE - Polyethylene outer jacket in Black, with an overall cable diameter (nominal) of 0.480 in (12.2 mm). Electrical characteristics include 78% nominal velocity of prop. and a voltage rating of 600 V (Center Conductor to inner Shield), 300 V (Between Shield).
Belden 9888 010 Key Features
- 50 Ohm triaxial coax construction (Triax 50Ω RG-8/U Type; RG type: 8; Coax type: RG 8).
- 11 AWG (7x19) BC - Bare Copper stranded conductor.
- PE - Polyethylene (Foam) insulation (Dielectric material: FPE-Foamed (Cellular) Polyethylene) with White color code.
- Double Braid Shield with Bare Copper (BC) braids: Inner Shield (Layer 1) 95% coverage and Outer Shield (Layer 1) 80% coverage; Flooded: No, not flooded over braid.
- Dual-jacket construction with PE - Polyethylene inner jacket and PE - Polyethylene outer jacket; Jacket Color: Black.
- Operating temperature range: -55°C to +80°C.
- Environmental suitability: Outdoor - Aerial, Outdoor, Sunlight Resistance - Black only, Aerial - When supported by messenger wire.
- Compliance and sustainability: CA Prop 65; EU CE Mark; EU Directive 2015/863/EU (RoHS 2 amendment); REACH; EU Directive 2011/65/EU (RoHS 2); EU Directive 2012/19/EU (WEEE); China RoHS II (GB/T 26572-2011).
Belden 9888 010 Applications
- Use in computer applications where a 50 Ohm triaxial coax is specified.
- Choose for instrumentation applications where consistent electrical characteristics and shielding are required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Conductor diameter (nom.) | 0.108 in |
| Insulation diameter (nom.) | 0.285 in (7.24 mm) |
| Inner jacket diameter (nom.) | 0.370 in (9.40 mm) |
| Outer jacket diameter (nom.) | 0.480 in (12.2 mm) |
| Installation min. bend radius | 4.8 in (120 mm) |
| Max Pull Tension | 326 lbs (148 kg) |
| Bulk cable weight | 130 lbs/1000ft |
| Nom. conductor DCR | 1.2 Ohm/1000ft |
| Nom. inner shield DCR | 1.2 Ohm/1000ft (3.9 Ohm/km) |
| Nom. outer shield DCR | 2.1 Ohm/1000ft (6.9 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 26.0 pF/ft (85.3 pF/m) |
| Attenuation @ 1 MHz | 0.10 dB/100ft |
| Attenuation @ 10 MHz | 0.50 dB/100ft |
| Attenuation @ 50 MHz | 1.20 dB/100ft |
| Attenuation @ 100 MHz | 1.80 dB/100ft |
| Attenuation @ 200 MHz | 2.70 dB/100ft |
| Attenuation @ 400 MHz | 4.20 dB/100ft |
| Attenuation @ 700 MHz | 5.80 dB/100ft |
| Attenuation @ 900 MHz | 6.70 dB/100ft |
| Attenuation @ 1000 MHz | 7.10 dB/100ft |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9888 010100, 9888 010250, 9888 010500, 9888 0101000, UPC 612825260028 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.