Belden 9936 060, 24 AWG 15C Shielded PVC, Chrome Jacket

SKU:Belden 9936 060
● In stock
Description
Belden 9936 060 is a 24 AWG 15-conductor shielded cable for computer communications and EIA RS-232/423 applications, including extended-distance RS-232 runs. It features 24 AWG stranded (7x32) tinned copper conductors with Datalene® insulation. For noise rejection, it includes an overall Beldfoil® shield (100% coverage) plus a tinned copper braid shield (65% coverage) with a drain wire. The chrome PVC jacket is intended for indoor installations where riser or plenum ratings are not required.
Belden 9936 060 Key Features
- 24 AWG 15-conductor shielded cable for computer communications and EIA RS-232/423 applications, including extended-distance RS-232 runs.
- 24 AWG stranded (7x32) tinned copper conductors with Datalene® insulation.
- Overall Beldfoil® (100% coverage) plus tinned copper braid shield (65% coverage) with a drain wire for noise rejection.
- Chrome PVC jacket for indoor installations where riser or plenum ratings are not required.
Belden 9936 060 Applications
- Specified for RS-232 extended distance & RS-423 applications, including extended-distance RS-232 runs.
- Supports computer communications wiring where shielded signal transmission is required.
- Well-suited for low voltage analog signals (4-20mA, 0-10V, ...).
- Also well-suited for low voltage digital control (24V, …).
- Can be used for line level audio signal connections.
- Suitable for panel wiring.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Number of Conductors | 15 |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene (Foam) |
| Nom. insulation thickness | 0.0125 in (0.318 mm) |
| Color Code | Black, White, Red, Green, Orange, Blue, White/Black Stripe, Red/Black Stripe, Green/Black Stripe, Orange/Black Stripe, Blue/Black Stripe, Black/White Stripe, Red/White Stripe, Green/White Stripe, Blue/White Stripe |
| Shield Type | Tape; Braid |
| Tape material | Bi-Laminate (Alum+Poly) |
| Tape coverage | 100% |
| Braid material | Tinned Copper (TC) |
| Braid coverage | 65% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Chrome |
| Nom. jacket thickness | 0.035 in (0.89 mm) |
| Nom. jacket diameter | 0.327 in (8.31 mm) |
| Overall cable diameter (nominal) | 0.327 in (8.31 mm) |
| Bulk cable weight | 59 lbs/1000ft (88 kg/km) |
| Nom. conductor DCR | 24 Ohm/1000ft (79 Ohm/km) |
| Nom. outer shield DCR | 3.56 Ohm/1000ft (11.7 Ohm/km) |
| Nom. capacitance cond-to-cond | 12 pF/ft (39 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 1.1 Amps per Conductor at 25ºC |
| UL Voltage Rating | 300 V (CM), 30 V (UL AWM 2919) |
| Operating temperature | -30°C to +80°C |
| UL temperature | 60°C (UL CM);80°C (UL AWM 2464) |
| Stationary min. bend radius | 3.9 in (99 mm) |
| Max Pull Tension | 118 lbs (53.5 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2919 |
| CEC / C(UL) compliance | CM |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Multi Conductor Cable |
| Other Part Numbers | 9936 060100, 9936 060250, 9936 060500, 9936 0601000, UPC 612825264552 |
| Priced Per | FT |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?