Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 9942 060, 22 AWG 6C Shielded 300V PVC Jacket, Chrome Jacket

Belden 9942 060

SKU:Belden 9942 060

Request a Quote

Request a Quote

Description

Specifications

Belden 9942 060, 22 AWG 6C Shielded 300V PVC Jacket, Chrome Jacket specifications
AttributeValue
Conductor countNumber Of Conductors: 6
Conductor sizeConductor Size: 22 AWG
Conductor strandingConductor Stranding: 7x30
Conductor MaterialConductor Material: TC - Tinned Copper
Insulation MaterialInsulation Material: SR-PVC - Polyvinyl Chloride (Semi-Rigid)
Insulation thickness (nom.)Nom. thickness: 0.011 in (0.28 mm)
Insulation diameter (nom.)Nom. Insulation Diameter: 0.050 in (1.3 mm)
Color CodeColor code: Black, White, Red, Green, Brown, Blue
Tape materialTape material: Bi-Laminate (Alum+Poly)
Tape coverageTape coverage: 100%
Braid materialBraid material: Tinned Copper (TC)
Braid coverageBraid coverage: 65%
Jacket MaterialJacket Material: PVC - Polyvinyl Chloride
Jacket ColorJacket Color: Chrome
Jacket thickness (nom.)Nom. Jacket thickness: 0.035 in (0.89 mm)
Overall cable diameter (nom.)Overall Cable Diameter (nominal): 0.245 in (6.22 mm)
Bulk cable weightBulk Cable Weight: 39 lbs/1000ft
Conductor DCR (nom.)Nom. Conductor DCR: 14.7 Ohm/1000ft
Outer shield DCR (nom)Nom outer Shield DCR: 7.9 Ohm/1000ft (26 Ohm/km)
Capacitance, Cond-to-Cond (nom.)Nom. capacitance Cond-to-Cond: 35 pF/ft (110 pF/m)
Capacitance, Cond-to-other (nom.)Nom. capacitance Cond-to-other (conds + Shield): 63 pF/ft (210 pF/m)
Max. currentMax. current: 1.5 Amps per Conductor at 25ºC
UL temperatureUL temperature: 60°C (UL CMG);80°C (UL AWM 2464)
Operating temperatureOperating temperature: -30°C to +80°C
Stationary min. bend radiusStationary min. Bend Radius: 2.9 in (74 mm)
Installation min. bend radiusInstallation min. Bend Radius: 2.9 in (74 mm)
Max Pull TensionMax. pull tension: 74.5 lbs (33.8 kg)
Environmental suitabilityEnvironmental suitability: Indoor (Not Riser or Plenum), Indoor
Flammability / reaction to fireFlammability / reaction to fire: UL 1685 FT4 Loading, FT4, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
NEC / UL complianceNEC / UL compliance: Article 800, CMG
AWM complianceAWM compliance: AWM 2464
CEC / C(UL) complianceCEC / C(UL) compliance: CMG
European directive complianceEuropean directive compliance: EU CE Mark
UK regulation complianceUKCA Mark
SustainabilitySustainability: CA Prop 65
Item TypeBelden Multi Conductor Cable
Other Part Numbers9942 060100, 9942 060250, 9942 060500, 9942 0601000, UPC 612825264767
Priced PerFT

Documents

Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.

Need a cut length, bulk pricing, or a spec sheet?

Our team quotes custom lengths and volume orders, usually same day.