Belden 1695A 877, Low Loss Serial Digital Coax 18 AWG FFEP

SKU:Belden 1695A 877
● In stock
Description
Belden 1695A 877 is a 75 Ohm SDI coax (RG type: 6) designed for low-loss serial digital video performance in plenum spaces. It features an 18 AWG solid BC - Bare Copper conductor with FEP - Fluorinated Ethylene Propylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. Shielding combines Duofoil® tri-laminate tape with a 95% tinned copper braid to help maintain signal integrity for digital video signals.
Key Features
- 75 Ohm SDI coax with coaxial construction and RG type: 6.
- 18 AWG solid BC - Bare Copper conductor (nom. diameter: 0.040 in).
- FEP - Fluorinated Ethylene Propylene (Foam) insulation (nom. insulation diameter: 0.170 in (4.32 mm); color code: White).
- Shielding: Duofoil® tri-laminate (Alum+Poly+Alum) tape at 100% coverage plus TC tinned copper braid at 95% coverage.
- PVC - Polyvinyl Chloride outer jacket with overall cable diameter (nominal): 0.229 in (5.82 mm).
- Environmental suitability: indoor - plenum, indoor; NEC / UL compliance: CMP; CEC / C(UL) compliance: CMP.
Applications
- Use in digital video installations requiring serial digital video performance.
- Support 6 Gb/s UHDTV signal runs in indoor plenum spaces.
- Enable HD-SDI 1080p video distribution in plenum-rated pathways.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Nom. characteristic impedance | 75 Ohm |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.2 pF/ft (53.1 pF/m) |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. outer shield DCR | 2.8 Ohm/1000ft (9.2 Ohm/km) |
| UL Voltage Rating | 300 V (CMP) |
| Return loss (5 - 1600 MHz) | 23 dB (min.) |
| Return loss (1600 - 4500 MHz) | 21 dB (min.) |
| Return loss (4500 - 6000 MHz) | 15 dB (min.) |
| Attenuation @ 1 MHz | 0.24 dB/100ft |
| Attenuation (3.58 MHz) | 0.45 dB/100ft |
| Attenuation @ 5 MHz | 0.55 dB/100ft |
| Attenuation @ 7 MHz | 0.65 dB/100ft |
| Attenuation @ 10 MHz | 0.75 dB/100ft |
| Attenuation (67.5 MHz) | 1.74 dB/100ft |
| Attenuation (71.5 MHz) | 1.78 dB/100ft |
| Attenuation (88.5 MHz) | 1.94 dB/100ft |
| Attenuation @ 100 MHz | 2.1 dB/100ft |
| Attenuation (135 MHz) | 2.4 dB/100ft |
| Attenuation (143 MHz) | 2.5 dB/100ft |
| Attenuation (180 MHz) | 2.8 dB/100ft |
| Attenuation (270 MHz) | 3.4 dB/100ft |
| Attenuation (360 MHz) | 4.0 dB/100ft |
| Attenuation (540 MHz) | 5.2 dB/100ft |
| Attenuation (720 MHz) | 6.1 dB/100ft |
| Attenuation (750 MHz) | 6.2 dB/100ft |
| Attenuation @ 1000 MHz | 7.4 dB/100ft |
| Attenuation (1500 MHz) | 9.5 dB/100ft |
| Attenuation (2000 MHz) | 11.3 dB/100ft |
| Attenuation (2250 MHz) | 12.2 dB/100ft |
| Attenuation (3000 MHz) | 14.6 dB/100ft |
| Attenuation (4500 MHz) | 18.6 dB/100ft |
| Attenuation (6000 MHz) | 22.4 dB/100ft |
| Operating | 0°C to +75°C |
| UL temperature | 75°C |
| Installation min. bend radius | 2.3 in (58 mm) |
| Max Pull Tension | 92 lbs (42 kg) |
| Bulk cable weight | 41 lbs/1000ft |
| Flammability / reaction to fire | NFPA 262 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Non-Plenum number | 1694A |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.