Belden DAUR 006, 4 23 CAT6A Riser Solid BC U/UTP PVC Blue

Description
Belden DAUR 006 is a Category 6A premise horizontal cable designed for high-performance Ethernet, including 10GBASE-T. It features 4 pair 23 AWG solid BC - Bare Copper conductors in a U/UTP (Unshielded Twisted Pair) design. This Riser-CMR cable uses a PVC - Polyvinyl Chloride jacket in Blue and includes a center member (Patented T-Spline®) with EquiBlock™ Barrier Technology. It is rated 300 V (CMR) and 75°C, with a frequency of 100 MHz.
Belden DAUR 006 Key Features
- Category 6A premise horizontal cable for Ethernet networks, including 10GBASE-T.
- Built with 4 pair 23 AWG solid BC - Bare Copper conductors in a U/UTP (Unshielded Twisted Pair) construction.
- Riser-CMR fire rating with a PVC - Polyvinyl Chloride jacket in Blue.
- Includes a center member (Patented T-Spline®) with EquiBlock™ Barrier Technology and a ripcord for easier installation handling.
- Electrical and handling ratings include UL voltage rating: 300 V (CMR) and UL temperature: 75°C.
Belden DAUR 006 Applications
- Use in premise horizontal cable runs where Category 6A performance is required.
- Enable Ethernet 10GBASE-T connectivity in network installations.
Belden™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.260 in (6.60 mm) |
| Insulation Material | PO - Polyolefin |
| Color Code | White & Blue, White & Orange, White & Green, White & Brown |
| Bulk cable weight | 31 lbs/1000ft (46 kg/km) |
| Plenum number | DAUP |
| Max. Conductor DCR | 82 Ohm/km (25 Ohm/1000ft) |
| Max. capacitance unbalance | 45 pF/100m |
| Max. delay | 537.6 ns/100m |
| Max. delay skew | 45 ns/100ft |
| Nom. velocity of prop. | 70% |
| Operating temperature | -20°C To +75°C |
| Storage temperature | -20°C To +75°C |
| Stationary min. bend radius | 1 in (25 mm) |
| Max Pull Tension | 25 lbs (11 kg) |
| Environmental suitability | Indoor - Riser, Indoor |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMR |
| ICEA compliance | S-116-732 |
| IEEE compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| NEMA Compliance | ANSI/NEMA WC-66 |
| TIA/EIA compliance | ANSI/TIA-568.2-D Category 6A |
| Third party performance verification | Channel/Category 6A |
| ISO/IEC compliance | ISO/IEC 11801-1, IEC 61156-5 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.