CommScope 106871809 1061C LB 4/24 W1000, Copper Cable PowerSUM Cat5e 24 AWG 4PR UTP PVC

SKU:106871809 1061C LB 4/24 W1000
● In stock
ft
Minimum order: 1,000 ft · Increments of 1,000 ft
Description
CommScope SYSTIMAX® PowerSUM 1061C is a Category 5e U/UTP horizontal twisted pair cable with 24 AWG solid bare copper conductors and a light blue PVC jacket for non-plenum installations. It supports network performance up to 200 MHz and is supplied in a 304.8 m | 1000 ft WE TOTE® box. The cable is designed to meet ANSI/TIA-568.2-D, CENELEC EN 50288-3-1, and ISO/IEC 11801 Class D transmission standards. It also supports IEEE 802.3 1000BASE-T (Gigabit Ethernet) and remote powering per IEEE 802.3bt (Type 4) when installed according to the referenced installation standards.
Key Features
- Category 5e U/UTP (unshielded) horizontal twisted pair cable for structured cabling runs.
- 24 AWG solid bare copper conductors in a 4-pair / 8-conductor construction.
- Polyolefin insulation with a light blue PVC jacket for non-plenum environments.
- Rated for operation up to 200 MHz.
- Supports IEEE 802.3 1000BASE-T (Gigabit Ethernet) and remote powering per IEEE 802.3bt (Type 4) when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A.
- Supplied as 304.8 m | 1000 ft in a WE TOTE® box.
Technical Specs
| Manufacturer | SYSTIMAX® |
|---|---|
| Product brand | PowerSUM |
| Product type | Twisted pair cable |
| Product number | 1061C |
| Cable component type | Horizontal |
| Transmission standards | ANSI/TIA-568.2-D | CENELEC EN 50288-3-1 | ISO/IEC 11801 Class D |
| Nominal velocity of propagation (NVP) | 69 % |
| Mutual capacitance | 5.6 nF/100 m @ 1 kHz |
| DC resistance, maximum | 9.38 ohms/100 m | 2.859 ohms/100 ft |
| DC resistance unbalance, maximum | 5 % |
| Operating voltage, maximum | 80 V |
| Dielectric strength, minimum | 1500 Vac | 2500 Vdc |
| Diameter over jacket, nominal | 5.207 mm | 0.205 in |
| Jacket thickness | 0.559 mm | 0.022 in |
| Pulling tension, maximum | 11.34 kg | 25 lb |
| Flame test method | CM |
| Installation temperature | 0 °C to +60 °C (+32 °F to +140 °F) |
| Operating temperature | -20 °C to +60 °C (-4 °F to +140 °F) |
| Weight | 29.168 kg/km | 19.6 lb/kft |
| CHINA-ROHS | Below maximum concentration value |
| REACH-SVHC | Compliant as per SVHC revision |
| ROHS | Compliant |
| UK-ROHS | Compliant |
Applications
- Use in horizontal structured cabling installations where Category 5e performance is required.
- Enable IEEE 802.3 1000BASE-T (Gigabit Ethernet) network links in standards-based LAN deployments.
- Fit non-plenum installation spaces where a PVC jacket and CM flame test method are specified.
- Support remote powering per IEEE 802.3bt (Type 4) when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A.
CommScope™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.