CommScope 760053835 D-006-LN-8W-F06NS, OS2 Single Mode 6 Fiber Outdoor Cable

Description
CommScope® 760053835 D-006-LN-8W-F06NS is a Fiber OSP Cable in the D-LN series with a stranded loose tube and gel-free subunit design, featuring a 6-fiber OS2 construction. It has a non-armored, all-dielectric build with a black PE jacket and jacket marking in feet. The fiber type is G.652.D and G.657.A1, TeraSPEED® | OS2, and it is qualified to ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20. Environmental space is Aerial, lashed | Buried, with installation temperature -30 °C to +70 °C (-22 °F to +158 °F) and operating temperature -40 °C to +70 °C (-40 °F to +158 °F).
Key Features
- Stranded loose tube cable type with a gel-free subunit design for cleaner field preparation.
- Non-armored, all-dielectric construction (Armored: No; All-dielectric: Yes).
- 6 total fibers with Fibers per subunit, quantity: 6 and Subunit, quantity: 1.
- Fiber type: G.652.D and G.657.A1, TeraSPEED® | OS2.
- Black PE jacket with Jacket UV resistance: UV stabilized and Jacket marking: feet.
- Qualified to ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20.
- Environmental space: Aerial, lashed | Buried.
Technical Specs
| Manufacturer | CommScope® |
|---|---|
| Product type | Fiber OSP Cable |
| Product series | D-LN |
| Construction type | Non-armored |
| Subunit type | Gel-free |
| Filler, quantity | 4 |
| Total fiber count | 6 |
| Self-support | No |
| Rodent protected | No |
| Jacket material | PE |
| Jacket color | Black |
| Buffer tube/subunit diameter | 2.5 mm | 0.098 in |
| Diameter over jacket | 10.2 mm | 0.402 in |
| Minimum bend radius, unloaded | 102 mm | 4.016 in |
| Minimum bend radius, loaded | 153 mm | 6.024 in |
| Tensile load, long term, maximum | 800 N | 179.847 lbf |
| Tensile load, short term, maximum | 2700 N | 606.984 lbf |
| Compression | 22 N/mm | 125.623 lbf/in |
| Compression test method | FOTP-41 | IEC 60794-1 E3 |
| Flex | 25 cycles |
| Flex test method | FOTP-104 | IEC 60794-1 E6 |
| Impact | 4.41 N-m | 39.032 in lb |
| Impact test method | FOTP-25 | IEC 60794-1 E4 |
| Strain | See long and short term tensile loads |
| Strain test method | FOTP-33 | IEC 60794-1 E1 |
| Twist | 10 cycles |
| Twist test method | FOTP-85 | IEC 60794-1 E7 |
| Vertical rise, maximum | 1307 m | 4288.058 ft |
| Installation temperature | -30 °C to +70 °C (-22 °F to +158 °F) |
| Operating temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage temperature | -40 °C to +75 °C (-40 °F to +167 °F) |
| Water penetration | 24 h |
| Water penetration test method | FOTP-82 | IEC 60794-1 F5 |
| Cable freeze | -2 °C | 28.4 °F |
| Cable freeze test method | FOTP-98 | IEC 60794-1 F15 |
| Heat age | -40 °C to +85 °C (-40 °F to +185 °F) |
| Heat age test method | IEC 60794-1 F9 |
| Low high bend | -30 °C to +60 °C (-22 °F to +140 °F) |
| Low high bend test method | FOTP-37 | IEC 60794-1 E11 |
| Temperature cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
| Temperature cycle test method | FOTP-3 | IEC 60794-1 F1 |
| Weight | 63 kg/km | 42.334 lb/kft |
Applications
- Supports outside plant installations in Aerial, lashed | Buried environmental space.
- Meets project requirements for ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-
CommScope™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.