CommScope 760053850 D-024-LN-8W-F12NS, OS2 Single Mode 24 Fiber Outdoor Cable

Description
CommScope® 760053850 D-024-LN-8W-F12NS is a D-LN series fiber OSP cable with a stranded loose tube, non-armored, gel-free construction. It is built with 24 fibers (12 fibers per subunit across 2 subunits) using G.652.D and G.657.A1, TeraSPEED® | OS2. The cable has a black PE jacket that is UV stabilized and marked in feet. It is specified for aerial, lashed | buried environments and includes defined mechanical, environmental, and compliance requirements.
Key Features
- CommScope® D-LN series fiber OSP cable
- Stranded loose tube design with non-armored, gel-free construction
- 24-fiber build with 12 fibers per subunit across 2 subunits
- Fiber type: G.652.D and G.657.A1, TeraSPEED® | OS2
- Black PE jacket that is UV stabilized and marked in feet
- Environmental space: aerial, lashed | buried
- Diameter over jacket: 10.2 mm | 0.402 in
- Weight: 63 kg/km | 42.334 lb/kft
Technical Specs
| Manufacturer | CommScope® |
|---|---|
| Product type | Fiber OSP Cable |
| Product series | D-LN |
| All-dielectric | Yes |
| Armored | No |
| Rodent protected | No |
| Self-support | No |
| Filler quantity | 3 |
| Buffer tube/subunit diameter | 2.5 mm | 0.098 in |
| Minimum bend radius, unloaded | 102 mm | 4.016 in |
| Minimum bend radius, loaded | 153 mm | 6.024 in |
| Tensile load, long term, maximum | 800 N | 179.847 lbf |
| Tensile load, short term, maximum | 2700 N | 606.984 lbf |
| Compression | 22 N/mm | 125.623 lbf/in |
| Compression test method | FOTP-41 | IEC 60794-1 E3 |
| Flex | 25 cycles |
| Flex test method | FOTP-104 | IEC 60794-1 E6 |
| Impact | 4.41 N-m | 39.032 in lb |
| Impact test method | FOTP-25 | IEC 60794-1 E4 |
| Strain | See long and short term tensile loads |
| Strain test method | FOTP-33 | IEC 60794-1 E1 |
| Twist | 10 cycles |
| Twist test method | FOTP-85 | IEC 60794-1 E7 |
| Vertical rise, maximum | 1307 m | 4288.058 ft |
| Installation temperature | -30 °C to +70 °C (-22 °F to +158 °F) |
| Operating temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage temperature | -40 °C to +75 °C (-40 °F to +167 °F) |
| Water penetration | 24 h |
| Water penetration test method | FOTP-82 | IEC 60794-1 F5 |
| Cable freeze | -2 °C | 28.4 °F |
| Cable freeze test method | FOTP-98 | IEC 60794-1 F15 |
| Heat age | -40 °C to +85 °C (-40 °F to +185 °F) |
| Heat age test method | IEC 60794-1 F9 |
| Low high bend | -30 °C to +60 °C (-22 °F to +140 °F) |
| Low high bend test method | FOTP-37 | IEC 60794-1 E11 |
| Temperature cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
| Temperature cycle test method | FOTP-3 | IEC 60794-1 F1 |
| Cable qualification standards | ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20 |
| CHINA-ROHS | Below maximum concentration value |
| REACH-SVHC | Compliant as per SVHC revision |
| ROHS | Compliant |
| UK-ROHS | Compliant |
Applications
- Use in outside plant deployments where aerial, lashed, or buried installation is required.
- Meet installations that require defined bend radius, tensile, compression, impact, twist, and flex performance limits.
- Fit projects that require UV stabilized jacketing and footage marking for identification and handling.
CommScope™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.