CommScope 760053918 D-144-LN-8W-F12NS, OS2 Single Mode 144 Fiber Outdoor Cable

Description
CommScope® 760053918 D-144-LN-8W-F12NS is an OS2 single-mode Fiber OSP Cable with a stranded loose tube, non-armored, all-dielectric design. It uses a gel-free subunit construction with dry water-blocking elements to support cleaner, faster cable preparation. The cable includes 144 fibers arranged as 12 subunits of 12 fibers each and features a black PE jacket that is UV stabilized and marked in feet. It is qualified to ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20.
Key Features
- Fiber type: G.652.D and G.657.A1, TeraSPEED® | OS2
- 144 fibers total, organized as 12 subunits with 12 fibers per subunit
- Stranded loose tube construction with a non-armored, all-dielectric design
- Gel-free subunit type with dry water-blocking elements
- Black PE jacket that is UV stabilized and marked in feet
- Cable qualification standards: ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20
Technical Specs
| Manufacturer | CommScope® |
|---|---|
| Product type | Fiber OSP Cable |
| Product series | D-LN |
| Rodent protected | No |
| Self-support | No |
| Buffer tube/subunit diameter | 2.5 mm | 0.098 in |
| Diameter over jacket | 15.7 mm | 0.618 in |
| Weight | 153 kg/km | 102.811 lb/kft |
| Minimum bend radius, unloaded | 157 mm | 6.181 in |
| Minimum bend radius, loaded | 236 mm | 9.291 in |
| Tensile load, long term, maximum | 800 N | 179.847 lbf |
| Tensile load, short term, maximum | 2700 N | 606.984 lbf |
| Compression | 22 N/mm | 125.623 lbf/in |
| Compression test method | FOTP-41 | IEC 60794-1 E3 |
| Impact | 5.15 N-m | 45.581 in lb |
| Impact test method | FOTP-25 | IEC 60794-1 E4 |
| Flex | 25 cycles |
| Flex test method | FOTP-104 | IEC 60794-1 E6 |
| Twist | 10 cycles |
| Twist test method | FOTP-85 | IEC 60794-1 E7 |
| Strain | See long and short term tensile loads |
| Strain test method | FOTP-33 | IEC 60794-1 E1 |
| Vertical rise, maximum | 533 m | 1748.688 ft |
| Environmental space | Aerial, lashed | Buried |
| Installation temperature | -30 °C to +70 °C (-22 °F to +158 °F) |
| Operating temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage temperature | -40 °C to +75 °C (-40 °F to +167 °F) |
| Water penetration | 24 h |
| Water penetration test method | FOTP-82 | IEC 60794-1 F5 |
| Cable freeze | -2 °C | 28.4 °F |
| Cable freeze test method | FOTP-98 | IEC 60794-1 F15 |
| Heat age | -40 °C to +85 °C (-40 °F to +185 °F) |
| Heat age test method | IEC 60794-1 F9 |
| Low high bend | -30 °C to +60 °C (-22 °F to +140 °F) |
| Low high bend test method | FOTP-37 | IEC 60794-1 E11 |
| Temperature cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
| Temperature cycle test method | FOTP-3 | IEC 60794-1 F1 |
| CHINA-ROHS | Below maximum concentration value |
| REACH-SVHC | Compliant as per SVHC revision |
| ROHS | Compliant |
| UK-ROHS | Compliant |
Applications
- Use in outside plant deployments where an all-dielectric, non-armored construction is required.
- Support aerial, lashed installations in OSP environments.
- Install in buried placement where the specified environmental space applies.
- Streamline field preparation and reduce mess during installation with gel-free subunits and dry water-blocking elements.
CommScope™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.