CommScope 760211417 Z-024-CN-RB-F12NS/8W/99F, Fiber Indoor Outdoor LSZH Riser 24 fiber Black

Description
CommScope® 760211417 is a Z-CN series fiber indoor/outdoor cable built with a ribbon central tube and a gel-free subunit design. It provides 24 total fibers arranged as 12 fibers per ribbon and supports G.652.D and G.657.A1 fiber type performance. This non-armored, all-dielectric cable uses a black LSZH jacket that is UV stabilized and includes feet jacket marking for easier cable management. It is listed for NEC OFNR (UL) and c(UL) with UL 1666 flame testing.
Key Features
- Z-CN series fiber indoor/outdoor cable for aerial (lashed), buried, and riser pathways.
- Ribbon central tube design with a gel-free subunit type.
- 24 total fibers with 12 fibers per ribbon, quantity: 12.
- Fiber type: G.652.D and G.657.A1.
- Non-armored construction with all-dielectric: Yes.
- Black LSZH jacket with UV stabilized jacket UV resistance and feet jacket marking.
- Flame test listing: NEC OFNR (UL) and c(UL); flame test method: UL 1666.
Technical Specs
| Manufacturer | CommScope® |
|---|---|
| Product type | Fiber indoor/outdoor cable |
| Product series | Z-CN |
| Buffer tube/subunit diameter | 6 mm | 0.236 in |
| Diameter over jacket | 13 mm | 0.512 in |
| Minimum bend radius, unloaded | 129.5 mm | 5.098 in |
| Minimum bend radius, loaded | 259.1 mm | 10.201 in |
| Tensile load, long term, maximum | 800 N | 179.847 lbf |
| Tensile load, short term, maximum | 2670 N | 600.24 lbf |
| Compression | 22 N/mm | 125.623 lbf/in |
| Compression test method | FOTP-41 | IEC 60794-1 E3 |
| Flex | 25 cycles |
| Flex test method | FOTP-104 | IEC 60794-1 E6 |
| Impact | 2.94 N-m | 26.021 in lb |
| Impact test method | FOTP-25 | IEC 60794-1 E4 |
| Strain | See long and short term tensile loads |
| Strain test method | FOTP-33 | IEC 60794-1 E1 |
| Twist | 10 cycles |
| Twist test method | FOTP-85 | IEC 60794-1 E7 |
| Installation temperature | -30 °C to +60 °C (-22 °F to +140 °F) |
| Operating temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage temperature | -40 °C to +75 °C (-40 °F to +167 °F) |
| Cable qualification standards | ANSI/ICEA S-104-696 | Telcordia GR-20 | Telcordia GR-409 |
| Water penetration | 24 h |
| Water penetration test method | FOTP-82 | IEC 60794-1 F5 |
| Heat age | -40 °C to +85 °C (-40 °F to +185 °F) |
| Heat age test method | IEC 60794-1 F9 |
| Low high bend | -30 °C to +60 °C (-22 °F to +140 °F) |
| Low high bend test method | FOTP-37 | IEC 60794-1 E11 |
| Temperature cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
| Temperature cycle test method | FOTP-3 | IEC 60794-1 F1 |
| Weight | 193 kg/km | 129.69 lb/kft |
| CHINA-ROHS | Below maximum concentration value |
| REACH-SVHC | Compliant as per SVHC revision |
| ROHS | Compliant |
| UK-ROHS | Compliant |
Applications
- Enables aerial (lashed) installations where an indoor/outdoor cable is required for routed fiber pathways.
- Works for buried deployments when the installation calls for a cable rated for buried environmental space.
- Meets riser pathway needs where NEC OFNR (UL) and c(UL) listing with UL 1666 flame testing is required.
- Simplifies installation tracking and cable management using feet jacket marking.
CommScope™ and all associated trademarks are the property of their respective owners.
Specifications
| Attribute | Value |
|---|---|
| Priced Per | FT |
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.