Southwire 11297906, Building Wire 4 AWG 1C Copper XHHW-2/RW90 Black
Description
Southwire 11297906 is a 4 AWG single-conductor copper building wire with black SIMpull XHHW-2/RW90 insulation. The conductor is Class B compressed stranded bare copper, 7 strands, per ASTM B3 and B8, insulated with flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) carrying Southwire's patented SIMpull Technology. XHHW-2 is rated 600 volts, or 1000 volts for sizes 8 and larger, and RW90 at 600 volts.
Southwire 11297906 Technical Specs
Conductor
| Conductor Size | 4 AWG |
|---|---|
| Metric Size | 21.2 mm² |
| Number of Conductors | 1 |
| Conductor | Class B compressed stranded bare copper |
| Strand Count | 7 |
| Diameter Over Conductor | 0.225 in (0.57 cm) |
Insulation
| Type | XHHW-2/RW90 |
|---|---|
| Insulation | Thermoset cross-linked polyethylene (XLPE), flame-retardant and moisture-resistant |
| Insulation Color | Black |
| Insulation Thickness | 45 mils (1.14 mm) |
Dimensions & Weight
| Approx. Outside Diameter | 0.321 in (0.82 cm) |
|---|---|
| Approx. Weight | 148 lbs/1000 ft (220 kg/km) |
| Copper Content | 128 lbs/1000 ft (190 kg/km) |
Thermal Rating
| Max. Conductor Temperature | 90°C, wet or dry locations |
|---|
Compliance
| Standards | ASTM B3, ASTM B8, ASTM B787, UL 44, CSA C22.2 No. 38, ICEA S-95-658 (NEMA WC70), Federal Specification A-A-59544, NMX-J-451-ANCE, NOM-063-SCFI |
|---|
Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661; and NEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable.
Southwire 11297906 Applications
- Services, feeders and branch-circuit wiring installed in conduit, cable tray or other recognized raceways.
- Pulls without pulling lubricant: SIMpull XHHW-2/RW90 conductors install without one.
- Health care facilities: Type XHHW-2 is suitable there per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 may be specified.
- Under the Canadian Electrical Code, RW90 suits open wiring, including open wiring exposed to the weather, and raceways other than cable troughs and ventilated flexible cableways, in dry or wet locations.
- Features: sunlight resistant; -40°C cold bend; FT1; Gasoline and Oil Resistant II; RoHS/REACH compliant.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.