Southwire 11308420, Building Wire 500 KCMIL Copper XHHW-2/RW90 Black
Description
Southwire 11308420 is a 500 KCMIL copper Type XHHW-2/RW90 building wire with black insulation. Its 37-strand Class B compressed bare copper conductor is insulated with flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) carrying Southwire's patented SIMpull Technology, so it is designed to be installed without pulling lubricant. XHHW-2 is rated 600 volts, or 1000 volts for sizes 8 and larger, and RW90 at 600 volts, for wet or dry locations not exceeding 90°C.
Southwire 11308420 Key Features
- SIMpull Technology insulation, which pulls without lubricant.
- Sunlight resistant, with a -40°C cold bend.
- Flame tests: FT1, and FT4 for 350 kcmil and larger.
- CT Rated for 1/0 AWG and larger.
- Gasoline and Oil Resistant II, and RoHS/REACH compliant.
Southwire 11308420 Technical Specs
Construction
| Conductor Size | 500 KCMIL |
|---|---|
| Metric Cross-Section | 253 mm² |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Number of Strands | 37 |
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Type Designation | XHHW-2/RW90 |
| Insulation Colour | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.789 in (2.00 cm) |
|---|---|
| Insulation Thickness | 65 mils (1.65 mm) |
| Approx. Overall Diameter | 0.908 in (2.31 cm) |
| Copper Content Weight | 1,543 lbs/1000 ft (2,296 kg/km) |
| Approx. Total Weight | 1,632 lbs/1000 ft (2,429 kg/km) |
Ratings
| XHHW-2 Voltage Rating | 600 volts, or 1000 volts for sizes 8 and larger |
|---|---|
| RW90 Voltage Rating | 600 volts |
| Temperature | Wet or dry locations, not to exceed 90°C |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| ASTM B787 | 19 Wire Combination Unilay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| IEEE 1202/FT4 | Flame Test (70,000 BTU/hr) 350kcmil and Larger |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| Federal Specification | A-A-59544 |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Southwire's standards statement for this wire also reads: Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 11308420 Applications
- Pulled into conduit, cable tray or other recognized raceways for services, feeders and branch circuit wiring.
- Type XHHW-2 is suitable for use in health care facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 may be specified.
- Under its RW90 designation it may be used for open wiring, including open wiring exposed to the weather, and in raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations, as per the Canadian Electrical Code.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.