Southwire 13890699, Machine Flex® XHHW-2 / RW90 Conductor 750 kcmil Copper Black
Description
Southwire 13890699 is a 750 kcmil Machine Flex® single conductor carrying the XHHW-2 designation at 1000 V and the RW90 designation at 600 V. Its 1850-strand, Class I flexible concentric rope-lay conductor is soft-drawn bare copper, insulated with black, sunlight, gas and oil resistant cross-linked polyethylene (XLPE). There is no separate jacket.
Southwire 13890699 Technical Specs
Conductor, Insulation & Dimensions
| Conductor Size | 750 KCMIL |
|---|---|
| Number of Conductors | 1 |
| Strands per Conductor | 1850 |
| Conductor | Class I, flexible concentric rope-lay stranded, soft-drawn bare copper |
| Insulation | Black, sunlight, gas and oil resistant cross-linked polyethylene (XLPE) |
| Insulation Thickness | 80 mils (2.03 mm) |
| Diameter Over Conductor | 1.094 in (2.78 cm) |
| Approximate Outside Diameter | 1.266 in (3.22 cm) |
| Approximate Weight | 2553 lbs/1000 ft (3799 kg/km) |
Ratings & Compliance
| Type and Voltage | XHHW-2 1000 V; RW90 600 V |
|---|---|
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger); CSA C22.2 No. 38 Thermoset-insulated wires and cables; ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
Sunlight Resistance. CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive; Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 13890699 Applications
- XHHW-2 and RW90 conductors are used in conduit, cable tray or other recognized raceways for service, feeders and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code).
- The voltage rating for XHHW-2 conductors is 600 volts and 1000 volts, and for RW90 conductors 600 volts.
- Conductor temperatures: not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload and 250°C for short circuit conditions.
- Flexible bare copper stranding eases installation where space is limited, and it also serves electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.