Southwire 13898401, SIM pull Nonmetallic Flexible Conduit 1/2 Inch Gray
Southwire · MPN 13898401
Description
Southwire 13898401 is SIM pull™ flexible nonmetallic conduit in the 1/2" trade size, gray. Rigid PVC reinforcement is embedded within a flexible PVC wall, giving excellent impact and crush strength while the conduit stays highly flexible, and SIM technology makes wire pulling easier. The conduit resists oils, mild acids and exposure to sunlight.
Southwire 13898401 Technical Specs
Dimensions
| Trade Size | 1/2" |
|---|---|
| Inside Diameter | 0.622 in (1.58 cm) |
| Outside Diameter (approx.) | 0.820 in (2.08 cm) |
| Minimum Bend Radius | 6.5 in (16.51 cm) |
Construction
| Material | Flexible PVC wall with rigid PVC reinforcement |
|---|---|
| Color | Gray |
Ratings & Standards
| Temperature Range | -30°C to 80°C; 60°C oil (-22°F to +176°F; 140°F oil) |
|---|---|
| Standards | UL 1660; CSA C22.2 No. 227.2.1; NFPA 70 (NEC) Article 356 |
Southwire 13898401 Applications
- Installs and protects electrical conductors in motor circuits, covering motor feeder, branch and control circuits and motor leads per NEC 430.145(B), for containment of 600 Volt and lower potential circuits.
- Fits installations where operation or maintenance calls for flexibility or protection from liquids, vapors, solids or weather, whether exposed or concealed, including runs that need movement, crossover connections or tight bends.
- Serves conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment in industrial and commercial settings, as well as agricultural buildings per NEC 547.5.
- Suitable for direct burial and for encasement in concrete.
- Makes flexible connections to swimming pool, spa and hot tub motors per NEC 680.21(A)(3) & 680.42(A)(1), and carries electric sign and outline lighting supply and secondary-circuit conductors per NEC 600.7, 600.31 (1000 volts or less) & 600.32 (over 1000 volts).
- Covers floating building feeders and services per NEC 553.7, boatyards and marinas per NEC 555.13, cranes and hoists per NEC 610.11(C), and elevators, dumbwaiters, escalators, moving walks, wheelchair lifts and stairway chair lifts per NEC 620.21 (where expressly permitted).
- Under raised floors, it carries information technology equipment conductors and cables per NEC 645.5 (D) & 645.5(D)(2).
- Service entrance in lengths up to six feet per NEC 230.43(15); approved for use in lengths longer than 6 feet per NEC 356.10(5).
- Class I, Div. 2 (NEC 501.10(B)(2)); Class II, Div. 1 (NEC 502.10(A)(2)); Class II, Div. 2 (NEC 502.10(B)(2)); Class III, Div. 1 (NEC 503.10(A)(2)); Class III, Div. 2 (NEC 503.10(B)).
- Seals out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated fixed alkalines, petroleum oils, salt air and spray, and weather, and its smooth interior eases wire pulling.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.