Southwire 13901599, Metal Clad Cable 250 KCMIL 4C with Ground Stranded Aluminum THHN 600 V
Description
Southwire 13901599 is an Armorlite® Type MC feeder cable with four 250 kcmil compact stranded 8000 series aluminum THHN/THWN conductors (brown, orange, yellow, gray) and a #2 green insulated aluminum ground under aluminum interlocked armor. Rated 600 V, with conductors rated 90°C dry.
Southwire 13901599 Technical Specs
Conductors and Insulation
| Conductor Size | 250 kcmil |
|---|---|
| Number of Conductors | 4, plus a grounding conductor |
| Conductor | Compact stranded 8000 series H14/H24 aluminum |
| Strands | 22 |
| Conductor Colors | Brown, Orange, Yellow, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 70 mils (1.78 mm) |
| Diameter Over Conductor | 0.520 in (1.32 cm) |
Grounding and Armor
| Grounding Conductor | Green insulated aluminum ground, #2 |
|---|---|
| Ground Size | 1x2 |
| Filler | Fillers as needed |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 1.916 in (4.87 cm) |
|---|---|
| Approximate Weight | 1,713 lbs per 1,000 ft (2,549 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Temperature Rating | 90°C dry, Type THHN/THWN |
| Anti-Short Bushing | Not required per NEC and UL |
Standards and Compliance
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS | Compliant; lead-free, silicone-free |
| Buy American | Compliant with Buy American requirements, 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 13901599 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Power and lighting circuits.
- Fishing or embedding in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Environmental air-handling spaces per NEC 300.22(C).
- Cable tray and approved raceways, or aerial installation on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.