Southwire 13926499, Machine Flex Flexible Tray Cable 12 AWG 9C Copper TC-ER Gray
Description
Southwire 13926499 is a 12 AWG 9-conductor Machine Flex flexible tray cable with Class K flexible stranded bare copper conductors, polyvinyl chloride (PVC) with nylon layer insulation and a gray sunlight resistant thermoplastic elastomer (TPE) jacket. One of the 9 conductors is a green ground with a yellow stripe. It is Type TC-ER/WTTC/ITC/PLTC/MTW.
Southwire 13926499 Technical Specs
Construction
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 9, one of them the green/yellow ground |
| Conductor | Class K flexible stranded bare annealed copper per ASTM B3, B172 and B174 |
| Strands per Conductor | 65 |
| Insulation | Polyvinyl chloride (PVC) with nylon layer, Type THHN |
| Conductor Identification | Numbered 1-ONE through 8-EIGHT, plus the green/yellow ground |
| Grounding Conductor | One green ground with yellow stripe, THHN |
| Jacket | Sunlight resistant gray thermoplastic elastomer (TPE) |
| Type Designation | TC-ER/WTTC/ITC/PLTC/MTW |
Dimensions and Weight
| Diameter Over Conductor | 0.094 in (0.24 cm) |
|---|---|
| Insulation Thickness | 20 mils (0.51 mm) |
| Jacket Thickness | 65 mils (1.65 mm) |
| Approx. Overall Diameter | 0.615 in (1.56 cm) |
| Minimum Bend Radius | 2.5 in (6.35 cm) |
| Copper Weight | 182 lbs/1000 ft (271 kg/km) |
| Approx. Total Weight | 291 lbs/1000 ft (433 kg/km) |
Electrical and Thermal Ratings
| Conductor Temperature | 75°C in wet locations and 90°C in dry locations; 130°C emergency overload; 150°C short circuit |
|---|---|
| Cold Impact | -40°C |
| DC Resistance at 25°C | 1.774 |
| AC Resistance at 75°C | 2.137 |
| Allowable Ampacity, Raceway, 75°C | 17 |
| Allowable Ampacity, Raceway, 90°C | 21 |
Standards
| ASTM B172 | Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors |
|---|---|
| ASTM B174 | Bunch-Stranded Copper |
| UL 13 | Power-Limited Circuit Cables |
| UL 83 | Thermoplastic Insulated Wire and Cables (sizes 14 AWG to 1000 kcmil) |
| UL 1063 | Machine Tool Wiring (MTW) |
| UL 1277 | TC-ER |
| UL 2250 | Instrumentation Tray Cable |
| UL 2277 | Type WTTC |
| CSA C22.2 No. 210 | Appliance wiring material products I/II A/B (Sizes 16 - 8AWG) |
| CSA C22.2 No.230 | Tray Cables - Rated TC |
| CSA C22.2 No. 239 | Control and instrumentation cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| NFPA 79 | Electrical Standard for Industrial Machinery |
| CE/RoHS-2 | The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
Southwire 13926499 Applications
- Wet and dry locations, in conduits, ducts, troughs and cable trays, and direct burial.
- Exposed runs (TC-ER) per NEC 336.10.
- Class I, II, Division 2 per NEC Articles 501 and 502.
- CNC machines, and grinding, cutting, metal forming, buffing and bottling equipment.
- Conveyors, processing and packaging equipment, assembly lines and control panels.
- Food and beverage, oil sands, plant expansion, wind energy and data centers.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.