Southwire 13962499, Metal Clad Cable 600 KCMIL 4C with Ground Stranded Copper THHN 600 V
Description
Southwire 13962499 is an Armorlite® Type MC feeder cable with four 600 kcmil class B compressed copper THHN/THWN conductors (purple, tan, pink, gray) and a #2/0 green insulated copper ground under aluminum interlocked armor. Rated 600 V, with conductors rated 90°C dry.
Southwire 13962499 Technical Specs
Conductors and Insulation
| Conductor Size | 600 kcmil |
|---|---|
| Number of Conductors | 4, plus a grounding conductor |
| Conductor | Class B compressed copper per ASTM B3 and ASTM B8 |
| Strands | 61 |
| Conductor Colors | Purple, Tan, Pink, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 80 mils (2.03 mm) |
| Diameter Over Conductor | 0.865 in (2.20 cm) |
Grounding and Armor
| Grounding Conductor | Green insulated stranded copper ground, #2/0 |
|---|---|
| Ground Size | 1x2/0 |
| Filler | Fillers as needed |
| Binder | Mylar tape with print legend wrapped around assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 2.772 in (7.04 cm) |
|---|---|
| Approximate Weight | 8,971 lbs per 1,000 ft (13,350 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Temperature Rating | 90°C dry, Type THHN/THWN |
| Anti-Short Bushing | Not required per NEC and UL |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American requirements, 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 13962499 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fishing or embedding in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.