Southwire 20513806, Building Wire 500 kcmil Copper SIMpull THHN-THWN-2 MTW Black
Description
Southwire 20513806 is a 500 kcmil copper SIMpull THHN/THWN-2 building wire, also designated MTW, in black. Its 37-strand compressed annealed bare copper conductor (ASTM B8) is insulated with heat and moisture resistant PVC under a nylon jacket utilizing SIMpull Technology, and it is designed to be installed without the application of a pulling lubricant. The voltage is 600 volts for all applications.
Southwire 20513806 Technical Specs
Construction
| Conductor Size | 500 kcmil |
|---|---|
| Conductor | Stranded compressed annealed bare copper per ASTM B8 |
| Number of Strands | 37 |
| Stranding Class | Class B (sizes 1 - 1000) |
| Insulation | Heat and moisture resistant PVC |
| Sheath | Nylon, utilizing SIMpull Technology |
| Type Designation | THHN-THWN-2 MTW |
| Insulation Color | Black |
Dimensions and Weight
| Diameter Over Conductor | 0.789 in (2.00 cm) |
|---|---|
| Insulation Thickness | 62 mils (1.57 mm) |
| Nylon Sheath Thickness | 9 mils (0.23 mm) |
| Approx. Overall Diameter | 0.931 in (2.36 cm) |
| Copper Content Weight | 1543 lbs/1000 ft (2296 kg/km) |
| Approx. Total Weight | 1662 lbs/1000 ft (2473 kg/km) |
Ratings
| Voltage | 600 volts, all applications |
|---|---|
| THHN | Dry locations not to exceed 90°C |
| THWN-2 | Wet or dry locations not to exceed 90°C, or 75°C when exposed to oil |
| MTW | Wet locations or when exposed to oil, not to exceed 60°C; dry locations not to exceed 90°C (ampacity limited to that for 75°C conductor temperature per NFPA 79) |
Features
| Sunlight | Sunlight resistant, #8 AWG and larger |
|---|---|
| Oil and Gasoline | Gasoline and Oil Resistant II |
| Cable Tray | CT Rated, 1/0 AWG and larger |
| VW-1 | All sizes |
| FT-1 | All sizes |
| RoHS | Compliant |
Standards
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
|---|---|
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1063 | Machine Tool Wiring (MTW) |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No. 75 | Thermoplastic Insulated Wires and Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| Federal Specification | A-A-59544 |
| NMX-J-010-ANCE | Thermoplastic insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Southwire 20513806 Applications
- Installed in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code and other applicable codes and standards.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.