Southwire 28828255, NM-B Cable 12 AWG 2C Copper with Ground
Description
Southwire 28828255 is a 12 AWG copper Type NM-B nonmetallic-sheathed cable from Southwire's Romex Brand SIMpull line, with 2 insulated conductors (black and white) and a 12 AWG bare copper ground. The solid copper conductors are PVC insulated under a nylon sheath, with a kraft paper binder inside a PVC jacket. The voltage rating is 600 volts for NM-B cable.
Southwire 28828255 Technical Specs
Construction
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 2 |
| Conductor Material | Solid bare copper per ASTM B3 |
| Stranding | Solid |
| Conductor Colours | Black, White |
| Ground | 12 AWG solid soft drawn bare copper with kraft paper wrap |
| Insulation | Polyvinyl chloride (PVC) with nylon sheath |
| Binder | Kraft paper |
| Jacket | PVC, utilizing SIMpull Technology |
Dimensions and Weight
| Diameter Over Conductor | 0.080 in (0.20 cm) |
|---|---|
| Insulation Thickness | 20 mils (0.51 mm) |
| Jacket Thickness | 25 mils (0.64 mm) |
| Approx. Cross-Section (flat) | 0.422 x 0.190 in (1.07 x 0.48 cm) |
| Copper Content Weight | 59 lbs/1000 ft (88 kg/km) |
| Approx. Total Weight | 87 lbs/1000 ft (129 kg/km) |
Ratings
| Voltage | 600 volts |
|---|---|
| Conductor Insulation | Rated 90°C, as required by the NEC and UL 719 for terminations in lighting fixtures |
| Ampacity | Limited to that for 60°C conductors |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| UL 719 | Nonmetallic-Sheathed Cables |
| Federal Specification | A-A-59544 |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| RoHS-2 | European Directive 2011/65/EU |
Southwire 28828255 Applications
- Used for both exposed and concealed work in dry locations, as specified in the National Electrical Code (NEC).
- NM-B cable is primarily used in residential wiring, as branch circuits for outlets, switches and other loads.
- Can be run in the air voids of masonry block or tile walls, where those walls are not wet or damp locations.
- Install it only as a complete cable: The individual conductors are not listed or marked as THHN conductors (or any other NEC recognized conductor type) and may not be installed apart from the cable, while conductors routed inside panelboards and boxes for termination count as part of it.