Southwire 44340801, Power Tray Cable 6 AWG 3C Copper THHN TC-ER 600V Black
Description
Southwire 44340801 is a 6 AWG, 3-conductor power tray cable with Class B compressed stranded bare copper conductors, polyvinyl chloride (PVC) with nylon layer Type THHN/THWN-2 insulation and a black PVC jacket. It is Type TC-ER and rated 600V. One 8 AWG green-insulated Class B compressed stranded copper grounding conductor runs with the three circuit conductors.
Southwire 44340801 Technical Specs
Construction
| Conductor Size | 6 AWG |
|---|---|
| Number of Conductors | 3 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Strands per Conductor | 7 |
| Insulation | Polyvinyl chloride (PVC) with nylon layer, Type THHN/THWN-2 |
| Conductor Identification | 1-Black, 2-Red, 3-Blue (ICEA S-58-679 Method 3) |
| Grounding Conductor | One 8 AWG green-insulated Class B compressed stranded copper, in addition to the circuit conductors |
| Filler | Polypropylene filler |
| Jacket | Polyvinyl chloride (PVC) |
| Jacket Colour | Black |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.177 in (0.45 cm) |
|---|---|
| Insulation Thickness | 30 mils (0.76 mm) |
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.734 in (1.86 cm) |
| Copper Weight | 297 lbs/1000 ft (442 kg/km) |
| Approx. Total Weight | 451 lbs/1000 ft (671 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 600V |
|---|---|
| Conductor Temperature | 90°C in dry or wet locations; 105°C emergency overload; 150°C short circuit |
| Environmental | Sunlight resistant; silicone free |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-58-679 | Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE) |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 44340801 Applications
- Wet and dry areas, in conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
- Exposed runs (TC-ER) per NEC 336.10.