Southwire 45741502, Metal Clad Cable 12 AWG 3C with Ground Stranded Copper THHN 600 V
Description
Southwire 45741502 is a SIM pull MC™ Type MC cable with three 12 AWG 19-strand copper THHN/THWN conductors (brown, orange, gray) and a green insulated ground conductor under aluminum interlocked armor. Rated 600 V, with conductors rated 90°C dry. Unjacketed; rated for dry, indoor locations only per NEC 330.10(A)(10).
Southwire 45741502 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 3, plus a grounding conductor |
| Conductor | 19-strand class C compressed copper per ASTM B3 and B8 |
| Conductor Colors | Brown, Orange, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.09 in (0.23 cm) |
Grounding and Armor
| Grounding Conductor | Green polyvinyl chloride with nylon sheath Type THHN/THWN insulated ground conductor |
|---|---|
| Ground Size | 1x12 |
| Binder | Mylar tape with print legend wrapped around assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.528 in (1.34 cm) |
|---|---|
| Approximate Weight | 140 lbs per 1,000 ft (208 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Temperature Rating | 90°C dry, Type THHN/THWN |
| Location | Dry, indoor locations only per NEC 330.10(A)(10) (unjacketed) |
| Anti-Short Bushing | Not required |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| VW-1 | Vertical-Wire) Flame Test |
| RoHS-2 | European Directive 2011/65/EU |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 45741502 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fishing or embedding in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.