Southwire 45767102, Metal Clad Cable 10 AWG 2C with Ground Stranded Copper THHN 600 V
Description
Southwire 45767102 is a SIM pull MC™ Type MC cable with two 10 AWG 19-strand copper THHN/THWN conductors, orange and gray, and a green insulated ground under aluminum interlocked armor. It is rated 600 V, with conductors rated 90°C dry, for dry, indoor locations.
Southwire 45767102 Technical Specs
Conductors and Insulation
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 2, plus a grounding conductor |
| Conductor | 19-strand class C compressed copper per ASTM B3 and B8 |
| Conductor Colors | Orange, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 25 mils (0.64 mm) |
| Diameter Over Conductor | 0.117 in (0.30 cm) |
Grounding and Armor
| Ground | Green polyvinyl chloride with nylon sheath Type THHN/THWN insulated ground conductor |
|---|---|
| Ground Size | 1x10 |
| Binder | Mylar tape; binder tape with print legend wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.573 in (1.46 cm) |
|---|---|
| Approximate Weight | 164 lbs per 1,000 ft (244 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry (Type THHN/THWN) |
| Location | Dry, indoor locations only per NEC 330.10(A)(10) (unjacketed) |
Standards and Compliance
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| VW-1 | Vertical-Wire Flame Test |
| RoHS-2 | European Directive 2011/65/EU |
| Made in America | Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661 |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 45767102 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
- Installs without anti-short bushings.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.