Southwire 55061199, Armored Cable 12 AWG 6C Copper XHHW-2 600 V Black
Description
Southwire 55061199 is a 12 AWG six-conductor Type MC-HL ARMOR-X® control cable rated 600 V. Its six 7-strand copper conductors carry 30 mils of XHHW-2 XLPE, and one 12 AWG green-insulated copper grounding conductor runs with them. ARMOR-X® continuous corrugated welded aluminum armor and a black polyvinyl chloride (PVC) outer jacket complete the cable.
Southwire 55061199 Technical Specs
Conductors & Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 6 |
| Strands per Conductor | 7 |
| Conductor | Class B compressed copper, 7 strands, per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 30 mils (0.76 mm) |
| Conductor Colors | Black 1, red 2, blue 3, orange 4, yellow 5, brown 6 |
Grounding, Armor & Jacket
| Grounding Conductor | One 12 AWG Class B compressed stranded copper with green insulation |
|---|---|
| Filler | Polypropylene, as needed |
| Binder | Polyester flat thread binder tape, as needed |
| Armor | ARMOR-X® continuous corrugated welded aluminum armor |
| Diameter Over Armor | 0.700 in (1.78 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 50 mils (1.27 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 0.806 in (2.05 cm) |
|---|---|
| Approximate Weight | 336 lbs/1000 ft (500 kg/km) |
| Copper Weight | 141 lbs/1000 ft (210 kg/km) |
| Minimum Bend Radius | 5.6 in (14.22 cm) |
Electrical Characteristics
| DC Resistance at 25 °C | 1.662 |
|---|---|
| AC Resistance at 75 °C | 2.002 |
| Allowable Ampacity in Raceway, 75 °C | 20 |
| Allowable Ampacity in Raceway, 90 °C | 24 |
Ratings & Compliance
| Voltage Rating | 600 V |
|---|---|
| Type Designation | Type MC-HL |
| Operating Temperatures | 90°C normal operation; 130°C emergency overload; 250°C short circuit |
| Cold Bend | -40°C |
| Location Rating | Class I, II, and III, Division 1 and 2 per NEC Article 501, 502, and 503 |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test; UL 2225 Cables and Cable-Fittings For Use In Classified Locations; ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2; ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables; ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy; IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr) |
Southwire 55061199 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, along with direct burial and aerial runs supported by a messenger.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.