Southwire 55094601, Ultratite Nonmetallic Flexible Conduit 1-1/2 Inch Gray
Description
Southwire 55094601 is a 1-1/2 inch Ultratite® flexible nonmetallic conduit in gray. Its flexible PVC wall has rigid PVC reinforcement embedded in it, which gives the conduit impact and crush strength while keeping it highly flexible. The conduit resists oils, mild acids and sunlight exposure.
The conduit is sealing out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated fixed alkalines, petroleum oils, salt air and spray, and weather. The interior is smooth for easier wire pulling, it accepts standard liquid-tight fittings, and it has a temperature range of -30°C to 80°C, 60°C in oil (-22°F to +176°F, 140°F in oil).
Southwire 55094601 Technical Specs
Dimensions
| Trade Size | 1-1/2 inch |
|---|---|
| Inside Diameter | 1.575 in (4.00 cm) |
| Outside Diameter (approx.) | 1.865 in (4.74 cm) |
| Weight (approx.) | 45 lbs per 1,000 ft (67 kg/km) |
| Minimum Bend Radius | 10.0 in (25.40 cm) |
Construction
| Construction | Flexible PVC wall with embedded rigid PVC reinforcement |
|---|---|
| Color | Gray |
Standards
| Standards | UL 1660; NFPA 70 (National Electrical Code) Article 356 |
|---|
Southwire 55094601 Applications
Suitable for:
- Installing and protecting electrical conductors, including the conductors of motor feeder, branch and control circuits.
- Locations where installation, operation or maintenance call for flexibility or for protection from liquids, vapors, solids or weather.
- Agricultural buildings per NEC 547.5.
- Industrial and commercial equipment such as conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment.
- Exposed or concealed runs, including runs that need movement, crossover connections or tight bends.
- Direct burial and encasement in concrete.
- Flexible connections to swimming pool, spa and hot tub motors per NEC 680.21(A)(3) & 680.42(A)(1).
- Supply and secondary-circuit conductors for electric signs and outline lighting per NEC 600.7, 600.31 (1000 volts or less) & 600.32 (over 1000 volts).
- Floating building feeders and services per NEC 553.7, and boatyards and marinas per NEC 555.13.
- Cranes and hoists per NEC 610.11(C); elevators, dumbwaiters, escalators, moving walks, wheelchair lifts and stairway chair lifts per NEC 620.21 (where expressly permitted).
- Information technology equipment conductors and cables under raised floors per NEC 645.5 (D) & 645.5(D)(2).
- Service entrance runs in lengths up to six feet per NEC 230.43(15).
- Containing circuits of 600 volts and lower.
- Lengths longer than 6 feet, as approved under NEC 356.10(5).
- Motor leads per NEC 430.145(B).
- Class I, Div. 2 (NEC 501.10(B)(2)); Class II, Div. 1 (NEC 502.10(A)(2)); Class II, Div. 2 (NEC 502.10(B)(2)); Class III, Div. 1 (NEC 503.10(A)(2)); Class III, Div. 2 (NEC 503.10(B)).