Southwire 55106101, Alflex Type RWA Aluminum Flexible Conduit 3 Inch
Description
Southwire 55106101 is a 3 inch Alflex™ Type RWA (Reduced Wall Aluminum) flexible metal conduit. A lightweight, high-strength aluminum alloy strip is formed helically into a continuously interlocked conduit that withstands impact and crushing forces.
Alflex Type RWA meets or exceeds UL 1, the Standard for Safety for Flexible Metal Conduit, and is UL Listed per UL 1; meets federal specification WW-C-566c; and is REACH/RoHS-2 (Chemical Limit) compliant. Its NEC type designation is Article 348, Type FMC (flexible metal conduit), and its UL product category is DXUZ. The conduit provides mechanical protection for conductors and cable, is for use with listed connectors intended for NEC Type FMC, and has a smooth interior for easy wire pulling and built-in flexibility for simpler positioning. The aluminum alloy construction is 66% lighter than steel, cutting 80% faster than steel, with superior corrosion resistance.
Southwire 55106101 Technical Specs
Dimensions
| Trade Size | 3 inch |
|---|---|
| Inside Diameter | 3.000 in (7.62 cm) |
| Outside Diameter (approx.) | 3.360 in (8.53 cm) |
| Minimum Bend Radius | 15.0 in (38.10 cm) |
Construction
| Construction | Continuously interlocked aluminum alloy strip |
|---|---|
| Wall | Reduced wall (RWA) |
Southwire 55106101 Applications
Suitable for:
- Environmental air-handling spaces per NEC 300.22(C).
- Power and lighting branch circuit conductors and cables connecting receptacles, luminaires, equipment, office partitions and similar loads.
- A metal raceway for wires and cables per NEC (ANSI/NFPA-70) Article 348, in concealed or exposed installations per NEC 348 and the applicable NEC provisions.
- Motor feeder, branch and control circuit conductors and cables.
- Class 1, Class 2 and Class 3 remote-control, signaling and power-limited circuit conductors and cables.
- Fire alarm system conductors and cables of power-limited or non-power-limited fire alarm circuits.
- Voice, data, communications and video cables, including CATV and optical fiber cables.
- Elevators, hoistways and escalators per NEC 620.21, and cranes and hoists per NEC 610.11(C).
- Listed wired fixtures per NEC 410.77(C).
- Raised floors for connection of information technology per NEC 645.5(D)(2) and 645.5(D).
- Serving as a grounding conductor for lengths up to 6 feet (20A max) as per NEC 250.118(5).
- Electric signs and outline lighting per NEC 600.7, 600.31 (1000 volts or less) and 600.32 (>1000 volts).
- Class 1, Div. 2, for flexible connectors only per NEC 501.10(B)(2) & 501.30(B).
- UL 1, 2 & 3 hour through-penetration firestop systems C-AJ-1462, C-AJ-1463, C-AJ-1464, W-L-1308 and W-L-1309.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.