Description
Southwire 55107899 is a 3 AWG copper SIMpull THHN-THWN-2 MTW building wire in brown. Its 19-strand bare copper conductor is insulated with heat and moisture resistant PVC under a nylon sheath utilizing SIMpull Technology, designed to be installed without a pulling lubricant. Rated 600 volts for all applications.
Southwire 55107899 Technical Specs
Construction
| Conductor Size | 3 AWG |
|---|---|
| Number of Conductors | 1 |
| Conductor | Stranded combination-unilay soft drawn annealed bare copper per ASTM B787 |
| Number of Strands | 19 |
| Insulation | Heat and moisture resistant PVC |
| Sheath | Nylon, utilizing SIMpull Technology |
| Type Designation | THHN-THWN-2 MTW |
| Insulation Colour | Brown |
Dimensions and Weight
| Diameter Over Conductor | 0.254 in (0.65 cm) |
|---|---|
| Insulation Thickness | 41 mils (1.04 mm) |
| Nylon Sheath Thickness | 7 mils (0.18 mm) |
| Approx. Overall Diameter | 0.350 in (0.89 cm) |
| Copper Content Weight | 162 lbs/1000 ft (241 kg/km) |
| Approx. Total Weight | 189 lbs/1000 ft (281 kg/km) |
Ratings
| Voltage | 600 volts, all applications |
|---|---|
| THHN | Dry locations, not to exceed 90°C |
| THWN-2 | Wet or dry locations, not to exceed 90°C, or 75°C when exposed to oil |
| MTW | Wet locations or exposed to oil, not to exceed 60°C; dry locations, not to exceed 90°C (ampacity limited to that for 75°C conductor temperature per NFPA 79) |
Features
| Stranding Class | Class C |
|---|---|
| Sunlight | Sunlight resistant, #8 AWG and larger |
| Oil and Gasoline | Gasoline and Oil Resistant II |
| Flame Tests | VW-1 and FT-1, all sizes |
| RoHS | Compliant |
Standards
| ASTM B787 | 19 Wire Combination Unilay-Stranded Copper Conductors |
|---|---|
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1063 | Machine Tool Wiring (MTW) |
| CSA C22.2 No. 75 | Thermoplastic Insulated Wires and Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| Federal Specification | A-A-59544 |
| NMX-J-010-ANCE | Thermoplastic insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Southwire 55107899 Applications
- Pulled into conduit for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code and other applicable codes and standards.