Southwire 55204699, Armored Cable 500 KCMIL 3C Copper 15 kV Black
Southwire · MPN 55204699
Description
Southwire 55204699 is a 500 KCMIL, three-conductor shielded medium-voltage armored cable rated 15 kV at 133% insulation level. Its 37-strand compressed bare copper conductors carry a semi-conducting conductor shield, 220 mils of no-lead ethylene propylene rubber (NL-EPR), a strippable insulation shield and a 5 mil copper tape shield, with three 1 AWG bare copper ground wires whose combined area is 50% of the phase conductor. A PVC inner jacket, aluminum interlocked armor (AIA) and a black PVC outer jacket complete the cable.
Southwire 55204699 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 37 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and ASTM B8 |
| Diameter Over Conductor | 0.789 in (2.00 cm) |
| Conductor Shield | Semi-conducting cross-linked copolymer |
| Insulation | No-lead ethylene propylene rubber (NL-EPR), 133% insulation level |
| Insulation Thickness | 220 mils (5.59 mm) |
| Diameter Over Insulation | 1.252 in (3.18 cm) |
| Conductor Colors | Black |
Shielding & Grounding
| Insulation Shield | Strippable semi-conducting cross-linked copolymer |
|---|---|
| Metallic Shield | 5 mil copper tape, helically wrapped with 25% overlap |
| Diameter Over Shield | 1.312 in (3.33 cm) |
| Grounding Conductors | Three 1 AWG Class B compressed stranded bare copper ground wires; combined circular mil area 50% of the phase conductor |
Armor & Jacket
| Filler | Wax paper |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | Polyvinyl chloride (PVC) |
| Inner Jacket Thickness | 75 mils (1.91 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 3.475 in (8.83 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 85 mils (2.16 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 3.645 in (9.26 cm) |
|---|---|
| Approximate Weight | 9544 lbs/1000 ft (14203 kg/km) |
| Maximum Pull Tension | 12000 lbs (5443.10 kg) |
| Minimum Bend Radius | 25.5 in (64.77 cm) |
Ratings
| Voltage Rating | 15 kV, 133% insulation level |
|---|---|
| Conductor Temperature | 105°C normal operation; 140°C emergency overload; 250°C short circuit |
| Maximum Sidewall Pressure | 1000 lbs/ft |
| Location Rating | Class I and II, Division 2 per NEC Article 501 and 502 |
| Silicone Free | Yes |
Standards
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 1072 Medium-Voltage Power Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
It is made in America and compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 55204699 Applications
- Wet and dry areas, conduits, ducts, troughs and trays.
- Direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.