Southwire 55276802, Metal Clad Cable 12 AWG 2C with Ground Solid Copper THHN 600 V Blue Armor
Description
Southwire 55276802 is an Armorlite® Type MC cable with two 12 AWG solid copper THHN/THWN conductors (brown and gray) and a green insulated ground under blue aluminum interlocked armor. It is rated 600 V, with conductors rated 90°C dry, and as unjacketed Type MC it is for dry, indoor locations only.
Southwire 55276802 Technical Specs
Conductors and Insulation
| Conductor Size | 12 AWG |
|---|---|
| Number of Conductors | 2, plus a grounding conductor |
| Conductor | Solid copper per ASTM B3 |
| Stranding | Solid |
| Conductor Colors | Brown, Gray |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.080 in (0.20 cm) |
Grounding and Armor
| Grounding | Green insulated ground, polyvinyl chloride with nylon sheath Type THHN/THWN |
|---|---|
| Ground Size | 1x12 |
| Binder | Mylar tape bearing the print legend |
| Armor | Blue aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.483 in (1.23 cm) |
|---|---|
| Approximate Weight | 105 lbs per 1,000 ft (156 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature | 90°C dry (Type THHN/THWN) |
| Location | Dry, indoor locations only per NEC 330.10(A)(10) |
| Anti-Short Bushing | Not required |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Meets or Exceeds | Federal Specification A-A59544 (formerly J-C-30B); NFPA 70 (National Electrical Code), Article 330 |
Southwire 55276802 Applications
- Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed runs.
- Environmental air-handling spaces per NEC 300.22(C).
- Power, lighting, control and signal circuits.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC Article 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.