Southwire 55299602, Metal Clad Cable 10 AWG 2C Neutral Per Phase Solid Copper THHN
Description
Southwire 55299602 is an Armorlite® Type MC neutral-per-phase cable with two 10 AWG solid copper THHN/THWN phase conductors, two 10 AWG neutrals and two 10 AWG insulated grounds under aluminum interlocked armor. Conductors are rated 90°C dry.
Southwire 55299602 Technical Specs
Conductors and Insulation
| Conductor Size | 10 AWG |
|---|---|
| Phase Conductors | 2 |
| Neutral Conductors | 2 x 10 AWG |
| Conductor Construction | Solid copper |
| Stranding | Solid |
| Wire Colors (phases, neutrals and grounds) | Black, Red, White, White-Blue, Green, Green-Yellow |
| Insulation | Polyvinyl chloride (PVC) with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 25 mils (0.64 mm) |
| Diameter Over Conductor | 0.101 in (0.26 cm) |
Grounding and Armor
| Grounding | 2 x 10 AWG insulated grounds, PVC with nylon sheath, Type THHN/THWN |
|---|---|
| Ground Size | 2x10 |
| Binder | Mylar tape with print legend wrapped around the assembly |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.671 in (1.70 cm) |
|---|---|
| Approximate Weight | 274 lbs per 1,000 ft (408 kg/km) |
Ratings
| Temperature Rating | 90°C dry (Type THHN/THWN) |
|---|---|
| Location | Dry, indoor locations only (unjacketed Type MC, NEC 330.10(A)(10)) |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
Meets or exceeds Federal Specification A-A59544 (formerly J-C-30B) and NFPA 70 (National Electrical Code), Article 330.
Southwire 55299602 Applications
- Neutral installation and marking in line with NEC 200.4; each neutral serves one circuit only (branch, multiwire branch or ungrounded feeder).
- Circuits affected by harmonics from non-linear switching loads such as computers, variable frequency drives, electrical test equipment and office equipment.
- Multiple circuits for branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22(C).
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(D)(2).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.