Southwire 55363102, Metal Clad Cable 10 AWG 3C with Ground Stranded Copper THHN Black Jacket
Description
Southwire 55363102 is an Armorlite® Type MC cable with three 10 AWG 19-strand copper THHN/THWN conductors, black, white and red, and a green insulated grounding conductor, under aluminum interlocked armor, with a black PVC jacket over the armor. Conductors rated 90°C dry and 75°C wet as Type THHN/THWN.
Southwire 55363102 Technical Specs
Conductors and Insulation
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 3, plus a grounding conductor |
| Conductor | 19-strand class C compressed copper per ASTM B3 and ASTM B8 |
| Stranding | 19 strands |
| Conductor Colors | Black, White, Red |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 25 mils (0.64 mm) |
| Diameter Over Conductor | 0.117 in (0.30 cm) |
Grounding and Armor
| Grounding | Green insulated ground, polyvinyl chloride with nylon sheath Type THHN/THWN |
|---|---|
| Ground Size | 1x10 |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
| Jacket | Black PVC, sunlight resistant, corrosion resistant |
| Jacket Thickness | 50 mils (1.27 mm) |
Dimensions and Weight
| Diameter Over Armor | 0.630 in (1.60 cm) |
|---|---|
| Approximate OD | 0.736 in (1.87 cm) |
| Approximate Weight | 297 lbs per 1,000 ft (442 kg/km) |
Ratings
| Conductor Temperature Rating | 90°C dry / 75°C wet, Type THHN/THWN |
|---|---|
| Location | Wet locations per NEC 330.10(A)(11) |
| Anti-Short Bushings | Not required |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| RoHS-2 | European Directive 2011/65/EU |
| Buy American | Compliant with Buy American Requirements, found in 49 U.S.C. 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | A-A59544 (formerly J-C-30B) |
| National Electrical Code | NFPA 70, Article 330 |
Southwire 55363102 Applications
- Branch and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Locations exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways, or aerial installation on a messenger.
- Under raised floors, for information technology equipment conductors and cables per NEC Article 645.
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.