Southwire 55454203, Fire Alarm Metal Clad Cable 14 AWG 2C + 16 AWG 2C Copper Red Armor
Description
Southwire 55454203 is a Red Alert® Type MC-FPL fire alarm composite cable with red aluminum interlocked armor. It combines a 14 AWG two-conductor element and a 16 AWG two-conductor element of solid copper with PVC and nylon sheath insulation. One of the two is a twisted shielded pair, with a tinned drain wire the same size as the pair conductors and an aluminum foil shield with blue laminate.
Southwire 55454203 Technical Specs
Conductors
| Construction | One 14 AWG two-conductor element and one 16 AWG two-conductor element |
|---|---|
| Conductor Material | Solid copper per ASTM B3 |
| Insulation | Polyvinyl chloride with nylon sheath |
| Insulation Thickness (14 AWG element) | 20 mils (0.51 mm) |
| Diameter Over Conductor (14 AWG element) | 0.064 in (0.16 cm) |
| 14 AWG Element Colors | Black, white |
Shield and Armor
| Shield | Aluminum foil with blue laminate |
|---|---|
| Drain Wire | Tinned, same size as the pair conductors |
| Binder | Mylar |
| Armor | Red aluminum interlocked armor |
Dimensions and Weight
| Approximate Outside Diameter | 0.665 in (1.69 cm) |
|---|---|
| Approximate Weight | 155 lbs/1000 ft (231 kg/km) |
Standards
| UL 1424 | Cables for Power-Limited Fire-Alarm Circuits |
|---|---|
| ASTM B3 | Soft or Annealed Copper Wire |
| UL 66 | Fixture Wire |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Fire Tests of Penetration Firestops |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
Southwire 55454203 Applications
- Wiring in plenums, ducts or other spaces used for environmental air-handling, per NEC 300.22(C) and 760.135(C).
- Power-limited and non-power-limited fire alarm circuits: smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices.
- Class 1, Class 2 and Class 3 remote control, signaling and power-limited circuits.
- Power, lighting, control and signal circuits.
- Fished or embedded in plaster; concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways, and under raised floors for information technology equipment per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
- Installs without anti-short bushings.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.