Southwire 55501903, Fire Alarm Metal Clad Cable 18 AWG 2 Shielded Pairs Copper TFN Red Armor
Description
Southwire 55501903 is a Red Alert® Type MC-FPL fire alarm cable with red aluminum interlocked armor, carrying two 18 AWG twisted shielded pairs, each pair with a tinned drain wire the same size as its conductors and an aluminum foil shield with blue laminate. The conductors are solid copper with PVC and nylon sheath insulation, Type TFN; there is no grounding conductor.
Southwire 55501903 Technical Specs
Conductors
| Conductor Size | 18 AWG |
|---|---|
| Number of Conductors | 4 (two pairs; no ground) |
| Conductor Material | Solid copper per ASTM B3 |
| Insulation | Polyvinyl chloride with nylon sheath, Type TFN |
| Insulation Thickness | 20 mils (0.51 mm) |
| Diameter Over Conductor | 0.040 in (0.10 cm) |
| Conductor Colors | Black/white and red/blue |
Shield and Armor
| Shield | Aluminum foil with blue laminate |
|---|---|
| Drain Wire | Tinned, same size as the pair conductors |
| Binder | Mylar |
| Armor | Red aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 0.564 in (1.43 cm) |
|---|---|
| Approximate Weight | 100 lbs/1000 ft (149 kg/km) |
Standards
| UL 1424 | Cables for Power-Limited Fire-Alarm Circuits |
|---|---|
| ASTM B3 | Soft or Annealed Copper Wire |
| UL 66 | Fixture Wire |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Fire Tests of Penetration Firestops |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
Southwire 55501903 Applications
- Wiring in plenums, ducts or other spaces used for environmental air-handling, per NEC 300.22(C) and 760.135(C).
- Power-limited and non-power-limited fire alarm circuits: smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices.
- Class 1, Class 2 and Class 3 remote control, signaling and power-limited circuits.
- Power, lighting, control and signal circuits.
- Fished or embedded in plaster; concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Cable tray and approved raceways, and under raised floors for information technology equipment per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.
- Installs without anti-short bushings.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.