Southwire 55615703, Building Wire 350 kcmil Copper SIMpull THHN-THWN-2 MTW Brown
Description
Southwire 55615703 is a 350 kcmil copper SIMpull THHN-THWN-2 MTW building wire with brown insulation. Its 37-strand Class B compressed annealed bare copper conductor is insulated with heat and moisture resistant PVC under a nylon sheath utilizing SIMpull Technology. Rated 600 volts for all applications.
Southwire 55615703 Technical Specs
Conductor and Construction
| Conductor Size | 350 kcmil |
|---|---|
| Number of Conductors | 1 |
| Strand Count | 37 |
| Conductor | Class B compressed stranded annealed bare copper per ASTM B8 |
| Insulation | Heat and moisture resistant PVC |
| Sheath | Nylon, utilizing SIMpull Technology |
| Insulation Color | Brown |
| Type Designation | THHN-THWN-2 MTW |
Dimensions and Weight
| Diameter Over Conductor | 0.661 in (1.68 cm) |
|---|---|
| Insulation Thickness | 62 mils (1.57 mm) |
| Nylon Sheath Thickness | 9 mils (0.23 mm) |
| Approx. Overall Diameter | 0.803 in (2.04 cm) |
| Copper Content Weight | 1080 lbs/1000 ft (1607 kg/km) |
| Approx. Total Weight | 1180 lbs/1000 ft (1756 kg/km) |
Electrical and Temperature Ratings
| Voltage | 600 volts, all applications |
|---|---|
| THHN | Dry locations, not to exceed 90°C |
| THWN-2 | Wet or dry locations, not to exceed 90°C, or 75°C when exposed to oil |
| MTW | Wet locations or exposed to oil, not to exceed 60°C; dry locations, not to exceed 90°C (ampacity limited to that for 75°C conductor temperature per NFPA 79) |
Features
| Sunlight | Sunlight resistant, #8 AWG and larger |
|---|---|
| Oil and Gasoline | Gasoline and Oil Resistant II |
| Cable Tray | CT Rated, 1/0 AWG and larger |
| Flame Tests | VW-1 and FT-1, all sizes |
| RoHS | RoHS Compliant |
Standards
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
|---|---|
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1063 | Machine Tool Wiring (MTW) |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No. 75 | Thermoplastic Insulated Wires and Cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| Federal Specification | A-A-59544 |
| NMX-J-010-ANCE | Thermoplastic insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Southwire 55615703 Applications
- Pulled into conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications, as specified in the National Electrical Code and other applicable codes and standards.
- SIMpull construction is designed so the wire can be installed without applying a pulling lubricant.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.