Southwire 55721501, Metal Clad Cable 4/0 AWG 3C with Ground Stranded Aluminum THHN 600 V
Description
Southwire 55721501 is an Armorlite® Type MC feeder cable with three 4/0 AWG compact stranded 8000 series aluminum THHN/THWN conductors, black, red and white, and a 2 AWG bare aluminum ground under aluminum interlocked armor. It is rated 600 V, with conductors rated 90°C dry and 75°C wet.
Southwire 55721501 Technical Specs
Conductors and Insulation
| Conductor Size | 4/0 AWG |
|---|---|
| Number of Conductors | 3, plus a grounding conductor |
| Conductor | Class B compact stranded 8000 series aluminum per ASTM B800 and ASTM B801 |
| Strands per Conductor | 19 |
| Conductor Colors | Black, Red, White |
| Insulation | Polyvinyl chloride with nylon sheath, Type THHN/THWN |
| Insulation Thickness | 60 mils (1.52 mm) |
| Diameter Over Conductor | 0.474 in (1.20 cm) |
Grounding and Armor
| Ground | Bare aluminum ground, 2 AWG |
|---|---|
| Ground Size | 1x2 |
| Filler | Fillers as needed |
| Binder | Mylar tape |
| Armor | Aluminum interlocked armor |
Dimensions and Weight
| Diameter Over Armor | 1.590 in (4.04 cm) |
|---|---|
| Approximate Weight | 1087 lbs per 1,000 ft (1618 kg/km) |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Conductor Temperature Rating | 90°C dry / 75°C wet (Type THHN/THWN) |
Standards and Compliance
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| UL 83 | Thermoplastic Insulated Wires and Cables |
| UL 1569 | Metal-Clad Cables |
| UL 1479 | Standard for Safety Fire Tests of Penetration Firestops |
| UL 1685 FT4 | Vertical-Tray Fire Propagation and Smoke Release Test |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
| Buy American | Compliant with Buy American requirements found in 49 U.S.C. § 5323(j), when ordered as “Made in the USA Only!” |
| Federal Specification | Meets or exceeds A-A59544 (formerly J-C-30B) |
| NFPA 70 (NEC) | Meets or exceeds Article 330 |
Southwire 55721501 Applications
- Feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Places of assembly per NEC 518.4 and theaters per NEC 520.5.
- Environmental air-handling spaces per NEC 300.22(C).
- Cable tray and approved raceways, or aerial runs on a messenger.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) and 645.5(E).
- Class I Div. 2, Class II Div. 2 and Class III Div. 1.