Southwire 56229701, Armored Cable 10 AWG 3C Copper 1 kV Black
Southwire · MPN 56229701
Description
Southwire 56229701 is a 10 AWG three-conductor Type TECK 90 armored cable rated 1 kV. Its three 7-strand copper conductors carry 45 mils of XLPE insulation color-coded black, red and blue, and an uninsulated Class B stranded grounding conductor runs with them. A black PVC inner jacket, aluminum interlocked armor (AIA) and a black PVC outer jacket complete the cable.
Southwire 56229701 Technical Specs
Conductors & Insulation
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 7 |
| Conductor | Class B stranded copper, compressed, per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 45 mils (1.14 mm) |
| Conductor Colors | BLACK/RED/BLUE |
Grounding, Armor & Jacket
| Grounding Conductor | One uninsulated Class B stranded grounding conductor |
|---|---|
| Inner Jacket | Black polyvinyl chloride (PVC) |
| Armor | Aluminum interlocked armor (AIA) |
| Diameter Over Armor | 0.785 in (1.99 cm) |
| Outer Jacket | Black polyvinyl chloride (PVC) |
| Jacket Thickness | 50 mils (1.27 mm) |
Electrical
| DC Resistance at 25°C | 1.040 |
|---|---|
| AC Resistance at 75°C | 1.253 |
| Allowable Ampacity, Raceway, 75°C | 35 |
| Allowable Ampacity, Raceway, 90°C | 40 |
Dimensions & Weight
| Approximate Outside Diameter | 0.885 in (2.25 cm) |
|---|---|
| Copper Weight | 117 lbs/1000' (174 kg/km) |
| Approximate Weight | 384 lbs/1000' (571 kg/km) |
| Minimum Bend Radius | 6.2 in (15.75 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV |
|---|---|
| Type Designation | Type TECK 90 |
| Sunlight Resistance | Sunlight resistant |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA AG14 - Acid Gas Compliance; ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2; ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
Southwire 56229701 Applications
- Exposed or concealed wiring in wet or dry locations.
- Ventilated, non-ventilated and ladder-type cable troughs and ventilated flexible cableway, in wet, dry or classified locations, or direct buried.
- Control, lighting and power circuits in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.