Southwire 56269299, Building Wire 700 kcmil Stranded Aluminum THHN/THWN-2 White
Description
Southwire 56269299 is a 700 kcmil single-conductor aluminum building wire in white, with 58-strand construction and the THHN/THWN-2 type designation. It is insulated with heat- and moisture-resistant PVC under a nylon jacket utilizing SIMpull Technology, and it is rated 600 volts.
Southwire 56269299 Technical Specs
Conductor & Dimensions
| Conductor Size | 700 kcmil |
|---|---|
| Conductor Material | Aluminum |
| Number of Conductors | 1 |
| Strands | 58 |
| Conductor | Class B compact stranded bare aluminum per ASTM B800 and ASTM B801, or Single Input Wire (SIW) compact aluminum per ASTM B836 |
| Diameter Over Conductor | 0.877 in (2.23 cm) |
| Insulation | Heat- and moisture-resistant PVC with a nylon jacket utilizing SIMpull Technology |
| Insulation Thickness | 70 mils (1.78 mm) |
| Nylon Jacket Thickness | 10 mils (0.25 mm) |
| Approx. Outside Diameter | 1.041 in (2.64 cm) |
| Aluminum Weight | 659 lbs/1000 ft (981 kg/km) |
| Approx. Weight | 811 lbs/1000 ft (1207 kg/km) |
| Insulation Colour | White |
Ratings
| Voltage Rating | 600 V |
|---|---|
| Type Designation | THHN/THWN-2 |
| THHN Temperature | Dry locations, not to exceed 90°C |
| THWN-2 Temperature | Wet or dry locations, not to exceed 90°C; not to exceed 75°C when exposed to oil |
| Features | Sunlight resistant, sizes #2 and larger; Oil and Gasoline Resistant II; CT, sizes 1/0 AWG and larger; VW-1, all sizes; FT1, all sizes; NEMA WC-70 construction requirements; RoHS compliant |
Compliance & Standards
| Standards | ASTM B800 8000 Series Aluminum Alloy Wire; ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy; ASTM B836 Compact Rounded Stranded Aluminum Conductors; UL 83 Thermoplastic Insulated Wires and Cables; CSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables; Federal Specification A-A-59544 |
|---|
Southwire 56269299 Applications
- Run in conduit and cable trays for services, feeders and branch circuits in commercial or industrial installations, as specified in the National Electrical Code and other applicable codes and standards.
- SIMpull Technology is designed to let the conductor be pulled in without applying a pulling lubricant.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.