Southwire 56303501, Instrumentation Cable 16 AWG 2 Pair Copper TC-ER 600V Black
Description
Southwire 56303501 is a 16 AWG instrumentation cable built from 2 twisted pairs (4 conductors) of 7-strand Class B bare copper. Each pair carries its own 100% coverage aluminum/polyester foil shield and drain wire, and the assembly is shielded again overall. The jacket is black sunlight, oil and moisture resistant PVC. The cable is rated 600V and -30°C to 90°C, Type TC-ER.
Rated for Class I Div II. Installations as outlined in NEC Article 336.
Southwire 56303501 Technical Specs
Conductors
| Conductor Size | 16 AWG |
|---|---|
| Number of Pairs | 2 |
| Total Conductors | 4 |
| Stranding | 7-strand, Class B |
| Conductor Material | Bare copper |
| Conductor Color Code | Black and white, alpha-numeric printed |
| Insulation | PVC plus nylon |
| Insulation Thickness | 15 mils (0.38 mm) |
| Diameter Over Conductor | 0.056 in (0.14 cm) |
Shielding and Jacket
| Shielding | 100% coverage aluminum/polyester foil over each pair, each with its own drain wire, plus a 100% coverage overall aluminum/polyester foil shield with a drain wire |
|---|---|
| Drain Wires | Tinned copper, two AWG sizes smaller than the pair size: 18 AWG for a 16 AWG pair |
| Binder | Mylar |
| Rip Cord | Under the jacket, for ease of removal |
| Jacket | Black sunlight, oil and moisture resistant PVC |
Dimensions and Weight
| Approximate Outside Diameter | 0.368 in (0.93 cm) |
|---|---|
| Jacket Thickness | 45 mils (1.14 mm) |
| Approximate Weight | 93 lbs/1000 ft (138 kg/km) |
| Minimum Bend Radius | 2.2 in (5.59 cm) |
Ratings and Standards
| Voltage Rating | 600V |
|---|---|
| Temperature Range | -30°C to 90°C |
| DC Resistance at 25°C, per Conductor | 4.181 |
| Type Designation | Type TC-ER |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 66 Fixture Wire Type TFN; UL 1277 Electrical Power and Control Tray Cables; UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method |
Southwire 56303501 Applications
- Process control and instrumentation circuits.
- Control circuits that operate and interconnect protective and signaling devices.
- General use in manufacturing, industrial and commercial distribution systems.
- Cable trays, raceways and conduit, along with aerial runs supported by a messenger and direct burial.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.