Southwire 56306999, Armored Cable 500 KCMIL 4C Copper XHHW-2 Type MC 600 V Black
Description
Southwire 56306999 is a 500 KCMIL four-conductor Type MC armored power cable rated 600 V. Its four 37-strand compressed copper conductors carry 65 mils of XHHW-2 XLPE, and one 2 AWG bare copper grounding conductor runs with them. ARMOR-X® continuous corrugated welded armor sits under a black Solonon® low smoke zero halogen (LSZH-TP) jacket. Part of the 600 Volt Type MC-HL ARMOR-X power cable line.
Southwire 56306999 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 4 |
| Strands per Conductor | 37 |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Insulation Thickness | 65 mils (1.65 mm) |
| Conductor Identification | 1-BLACK/2-RED/3-BLUE/4-ORANGE |
| Diameter Over Conductor | 0.789 in (2.00 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 2 AWG Class B compressed stranded bare copper grounding conductor |
|---|---|
| Filler | Paper |
| Binder | Polypropylene tape |
| Armor | ARMOR-X® continuous corrugated welded armor |
| Diameter Over Armor | 2.670 in (6.78 cm) |
| Outer Jacket | Black thermoplastic Solonon® low smoke zero halogen (LSZH-TP) |
| Jacket Thickness | 75 mils (1.91 mm) |
Dimensions & Weight
| Approximate Outside Diameter | 2.820 in (7.16 cm) |
|---|---|
| Approximate Weight | 7756 lbs/1000' (11542 kg/km) |
| Maximum Pull Tension | 12800 lbs (5805.98 kg) |
| Minimum Bend Radius | 19.7 in (50.04 cm) |
Ratings & Compliance
| Voltage Rating | 600 V |
|---|---|
| Type Designation | Type MC |
| Operating Temperatures | 90°C normal operation; 130°C emergency overload; 250°C short circuit; -40°C cold bend |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; UL 44 Thermoset-Insulated Wires and Cables; UL 1569 Metal-Clad Cables; UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test; UL 2225 Cables and Cable-Fittings For Use In Classified Locations; ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE); ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy; IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil & Larger) |
Southwire 56306999 Applications
- Wet and dry areas, conduits, ducts, troughs and trays, along with direct burial and aerial runs supported by a messenger.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.