Southwire 56861199, Armored Cable 10 AWG 4C Copper 1 kV Black
Description
Southwire 56861199 is a 10 AWG four-conductor Teck 90 armored cable rated 1 kV, finished in a black PVC outer jacket over aluminum interlocked armor (AIA). Its 7-strand Class B copper conductors carry 45 mils of cross-linked polyethylene (XLPE) insulation identified black, red, blue and white, and are cabled with one 12 AWG uninsulated Class B stranded grounding conductor under a black PVC inner jacket. Standards include CSA C22.2 No. 131 Type TECK 90 Cable.
Southwire 56861199 Technical Specs
Conductors & Insulation
| Conductor Size | 10 AWG |
|---|---|
| Number of Conductors | 4 |
| Strands per Conductor | 7 |
| Conductor | Class B stranded copper, compressed or compact, per ASTM B3 and B8 |
| Insulation | Cross-linked polyethylene (XLPE) |
| Insulation Thickness | 45 mils (1.14 mm) |
| Conductor Identification | Black, red, blue and white |
| Diameter Over Conductor | 0.113 in (0.29 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 12 AWG uninsulated Class B stranded grounding conductor |
|---|---|
| Inner Jacket | Black PVC |
| Inner Jacket Thickness | 65 mils (1.65 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Outer Jacket | Black PVC |
| Outer Jacket Thickness | 45 mils (1.14 mm) |
Dimensions & Weight
| Diameter Over Armor | 0.833 in (2.12 cm) |
|---|---|
| Approximate Outside Diameter | 0.923 in (2.34 cm) |
| Approximate Weight | 435 lbs/1000 ft (647 kg/km) |
| Maximum Pull Tension | 332 lbs (150.59 kg) |
| Minimum Bend Radius | 6.4 in (16.26 cm) |
Ratings & Compliance
| Voltage Rating | 1 kV |
|---|---|
| Temperature Ratings | 90°C maximum continuous operating; -40°C CSA cold bend and impact; -40°C minimum installation |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods; CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; CSA AG14 - Acid Gas Compliance; IEEE 383 Flame Test (70,000 btu); IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 56861199 Applications
- Exposed or concealed wiring in wet or dry locations; the cable is sunlight resistant.
- Ventilated, non-ventilated and ladder-type cable troughs and ventilated flexible cableway, in wet, dry or classified locations.
- Typical circuits are control, lighting and power in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.