Southwire 56892799, Armored Cable 500 KCMIL 3C Copper 5 kV Orange
Description
Southwire 56892799 is a 500 kcmil three-conductor Teck 90 armored power cable rated 5 kV, non-shielded, with an orange PVC outer jacket over aluminum interlocked armor (AIA). Each 37-strand Class B copper conductor has an extruded semi-conducting conductor shield and 90 mils of TRXLPE (tree-retardant cross-linked polyethylene) insulation rated 90°C; one 3 AWG bare copper grounding conductor and polypropylene binder tape sit beneath a black PVC inner jacket.
Southwire 56892799 Technical Specs
Conductors & Insulation
| Conductor Size | 500 KCMIL |
|---|---|
| Number of Conductors | 3 |
| Strands per Conductor | 37 |
| Conductor | Class B stranded copper, compressed or compact, per ASTM B3 and B8 |
| Conductor Shield | Extruded semi-conducting thermosetting polymeric layer |
| Insulation | TRXLPE, 90°C |
| Insulation Thickness | 90 mils (2.29 mm) |
| Diameter Over Conductor | 0.789 in (2.00 cm) |
Grounding, Armor & Jacket
| Grounding Conductor | One 3 AWG Class B compressed or compact stranded bare copper |
|---|---|
| Binder | Polypropylene tape |
| Inner Jacket | Black PVC |
| Inner Jacket Thickness | 115 mils (2.92 mm) |
| Armor | Aluminum interlocked armor (AIA) |
| Outer Jacket | Orange PVC |
| Outer Jacket Thickness | 65 mils (1.65 mm) |
Dimensions & Weight
| Diameter Over Armor | 2.731 in (6.94 cm) |
|---|---|
| Approximate Outside Diameter | 2.863 in (7.27 cm) |
| Approximate Weight | 6713 lbs/1000 ft (9990 kg/km) |
| Maximum Pull Tension | 12000 lbs (5443.10 kg) |
| Minimum Bend Radius | 20.0 in (50.80 cm) |
Ratings & Compliance
| Voltage Rating | 5 kV, non-shielded |
|---|---|
| Temperature Ratings | 90°C maximum continuous operating; 140°C emergency overload; 250°C short circuit; -40°C CSA cold bend and impact; -25°C minimum installation |
| Standards | ASTM B3 Soft or Annealed Copper Wire; ASTM B8 Concentric-Lay-Stranded Copper Conductors; CSA C22.2 No. 174; CSA C22.2 No. 131 Type TECK 90 Cable; CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods; CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating; CSA HL rating; CSA SUN RES - for Sunlight Resistant rating; CSA AG14 - Acid Gas Compliance; ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables; IEEE 383 Flame Test (70,000 btu); IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test; FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test) |
Southwire 56892799 Applications
- The Teck 90, 5000V, non-shielded, TRXLPE insulated (treeing resistant) power cable is a CSA approved armoured cable for industrial and commercial medium voltage applications, rated FT4, -40°C, HL, AG14 and 90°C for harsh Canadian environments.
- Installation methods are cable trays, duct banks, direct burial, troughs, classified locations and continuous rigid cable supports.
- The cable may also be encased in concrete.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.