Southwire 57095999, Power Tray Cable 6 AWG 2C Copper XHHW-2 TC 1000V Black
Description
Southwire 57095999 is a 6 AWG, 2-conductor Type TC power tray cable with Class B compressed stranded bare copper conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation, one 8 AWG green-insulated grounding conductor and a black polyvinyl chloride (PVC) jacket. It is rated 1000V.
Southwire 57095999 Technical Specs
Construction
| Conductor Size | 6 AWG |
|---|---|
| Number of Conductors | 2, plus one grounding conductor |
| Conductor | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Strands per Conductor | 7 |
| Insulation | Cross-linked polyethylene (XLPE), Type XHHW-2 |
| Conductor Identification | 1-Black, 2-Red |
| Grounding Conductor | One 8 AWG green-insulated Class B compressed stranded copper |
| Filler and Binder | Paper filler and binder tape as needed |
| Jacket | Black polyvinyl chloride (PVC) |
| Type Designation | TC |
Dimensions and Weight
| Diameter Over Conductor | 0.177 in (0.45 cm) |
|---|---|
| Insulation Thickness | 45 mils (1.14 mm) |
| Jacket Thickness | 60 mils (1.52 mm) |
| Approx. Overall Diameter | 0.691 in (1.76 cm) |
| Copper Weight | 215 lbs/1000 ft (320 kg/km) |
| Approx. Total Weight | 341 lbs/1000 ft (507 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| Other | Silicone free |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| IEEE 383 | Flame Test (70,000 btu) |
| IEEE 1202 FT4 | Flame Test (70,000) BTU/hr Vertical Tray Test |
Southwire 57095999 Applications
- Wet and dry areas: conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Class I, II and III, Division 2 per NEC Article 501 and 502.