Southwire 57634904, Building Wire 600 kcmil Aluminum XHHW-2/RW90 Gray
Description
Southwire 57634904 is a 600 kcmil aluminum SIMpull XHHW-2/RW90 building wire with gray insulation, part of Southwire's XHHW-2/RW90 line built with AlumaFlex Brand conductors. A compact stranded aluminum conductor carries flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) insulation with patented SIMpull Technology, and The wire can be installed without pulling lubricant. Rated up to 1000 volts for all applications, in wet or dry locations at conductor temperatures not exceeding 90°C.
Southwire 57634904 Technical Specs
Construction
| Conductor Size | 600 kcmil |
|---|---|
| Metric Cross-Section | 304 mm² |
| Conductor | Class B compact stranded bare aluminum per ASTM B800 and ASTM B801, or Single Input Wire (SIW) compact aluminum per ASTM B836 |
| Number of Strands | 37 |
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Insulation Color | Gray |
| Type Designation | XHHW-2/RW90 |
Dimensions and Weight
| Diameter Over Conductor | 0.812 in (2.06 cm) |
|---|---|
| Insulation Thickness | 80 mils (2.03 mm) |
| Approx. Overall Diameter | 0.981 in (2.49 cm) |
| Aluminum Content Weight | 565 lbs/1000 ft (841 kg/km) |
| Approx. Total Weight | 681 lbs/1000 ft (1013 kg/km) |
Ratings
| Voltage | Up to 1000 volts, all applications |
|---|---|
| Temperature | Wet or dry locations, not to exceed 90°C |
Features
| Cable Tray | CT Rated, sizes 1/0 AWG and larger |
|---|---|
| Flame Test | FT4, 350 kcmil and larger |
| Gas and Oil | Gas and Oil Resistant II, all sizes |
| Sunlight | Sunlight Resistant, sizes 6 AWG and larger |
| NOM-ANCE | XHHW-2, 90ºC |
| Federal Specification | AA-59544 |
| RoHS/REACH | Compliant |
Standards
| ASTM B800 | 8000 Series Aluminum Alloy Wire |
|---|---|
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
Southwire 57634904 Applications
- Installed in conduit and cable trays for services, feeders and branch circuits in commercial or industrial work, as the National Electrical Code specifies.
- It is suitable for health care facilities under NEC section 517.160 where a dielectric constant of 3.5 or less may be specified.
- Under its RW90 designation it serves open wiring, including open wiring exposed to the weather, and raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations, per the Canadian Electrical Code.
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.