Southwire 57853899, Power Tray Cable 750 kcmil 4C Aluminum Alloy XHHW-2 TC-ER 1000V Black
Description
Southwire 57853899 is a 750 kcmil, 4-conductor Type TC-ER power tray cable with Class B compact stranded 8000 Series aluminum alloy conductors, cross-linked polyethylene (XLPE) Type XHHW-2 insulation, one bare 1/0 AWG aluminum alloy grounding conductor and a black polyvinyl chloride (PVC) jacket. It is rated 1000V.
Southwire 57853899 Technical Specs
Construction
| Conductor Size | 750 kcmil |
|---|---|
| Number of Conductors | 4, plus one grounding conductor |
| Conductor | Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836 |
| Strands per Conductor | 58 |
| Insulation | Cross-linked polyethylene (XLPE) Type XHHW-2 |
| Conductor Identification | 1-Black, 2-Red, 3-Blue, 4-Orange |
| Grounding Conductor | One 1/0 AWG Class B compact stranded 8000 Series aluminum, bare |
| Filler and Binder | Paper filler; polyester flat thread binder tape |
| Jacket | Black polyvinyl chloride (PVC) |
| Type Designation | TC-ER |
Dimensions and Weight
| Diameter Over Conductor | 0.908 in (2.31 cm) |
|---|---|
| Insulation Thickness | 80 mils (2.03 mm) |
| Jacket Thickness | 140 mils (3.56 mm) |
| Approx. Overall Diameter | 2.858 in (7.26 cm) |
| Aluminum Weight | 2954 lbs/1000 ft (4396 kg/km) |
| Approx. Total Weight | 4296 lbs/1000 ft (6393 kg/km) |
Electrical and Thermal Ratings
| Voltage Rating | 1000V |
|---|---|
| Conductor Temperature | 90°C normal operation in wet and dry locations; 130°C emergency overload; 250°C short circuit |
| Other | Silicone free |
Standards
| ASTM B801 | Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy |
|---|---|
| ASTM B836 | Compact Rounded Stranded Aluminum Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1277 | Electrical Power and Control Tray Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
Southwire 57853899 Applications
- Wet and dry areas: conduits, ducts, troughs and cable trays.
- Direct burial, and aerial runs supported by a messenger.
- Exposed runs as Type TC-ER per NEC 336.10.
- Class I, II and III, Division 2 per NEC Article 501 and 502.
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.