Southwire 58012199, Building Wire 300 kcmil Copper XHHW-2/RW90 Green
Description
Southwire 58012199 is a 300 kcmil copper SIMpull XHHW-2/RW90 building wire in green. Its Class B compressed stranded bare copper conductor is insulated with flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with patented SIMpull Technology, and it installs without pulling lubricant. It may be used in wet or dry locations at temperatures not exceeding 90°C.
Southwire 58012199 Technical Specs
Construction
| Conductor Size | 300 kcmil |
|---|---|
| Metric Cross-Section | 152 mm² |
| Conductor Material | Class B compressed stranded bare copper per ASTM B3 and B8 |
| Number of Strands | 37 |
| Insulation | Flame-retardant, moisture-resistant thermoset cross-linked polyethylene (XLPE) with SIMpull Technology |
| Type Designation | XHHW-2/RW90 |
| Insulation Colour | Green |
Dimensions and Weight
| Diameter Over Conductor | 0.610 in (1.55 cm) |
|---|---|
| Insulation Thickness | 65 mils (1.65 mm) |
| Approx. Overall Diameter | 0.732 in (1.86 cm) |
| Copper Content Weight | 926 lbs/1000 ft (1378 kg/km) |
| Approx. Total Weight | 992 lbs/1000 ft (1476 kg/km) |
Ratings
| XHHW-2 Voltage | 600 volts, or 1000 volts for sizes 8 and larger |
|---|---|
| RW90 Voltage | 600 volts |
| Temperature | Wet or dry locations, not to exceed 90°C |
Features
| Cable Tray | CT Rated, 1/0 AWG and larger |
|---|---|
| Sunlight | Sunlight resistant |
| Cold Bend | -40°C cold bend |
| Flame Test | FT1 |
| Oil and Gasoline | Gasoline and Oil Resistant II |
| RoHS/REACH | Compliant |
Standards
| ASTM B3 | Soft or Annealed Copper Wire |
|---|---|
| ASTM B8 | Concentric-Lay-Stranded Copper Conductors |
| UL 44 | Thermoset-Insulated Wires and Cables |
| UL 1685 | Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger) |
| CSA C22.2 No. 38 | Thermoset-insulated wires and cables |
| ICEA S-95-658 (NEMA WC70) | Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy |
| Federal Specification | A-A-59544 |
| NMX-J-451-ANCE | Thermoset insulated wires and cables |
| NOM-063-SCFI | Electrical Products – Conductors – Safety Requirements |
| NEMA 70901-2-2024 | Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire & Cable |
Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.
Southwire 58012199 Applications
- Installed in conduit, cable tray or other recognized raceways for services, feeders and branch circuit wiring.
- Type XHHW-2 is suitable for use in health care facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 may be specified.
- As RW90 it suits open wiring, including open wiring exposed to the weather, and raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations, as per the Canadian Electrical Code.
Documents